Evidence map›Paper›PMID 35286082›Full record

ArticleACS applied materials & interfaces2022

Designing Electrochemical Biosensing Platforms Using Layered Carbon-Stabilized Porous Silicon Nanostructures.

Keying Guo, Maria Alba, Grace Pei Chin, Ziqiu Tong, Bin Guan, Michael J Sailor, Nicolas H Voelcker, Beatriz Prieto-Simón

Abstract read
In one paragraph

Article in ACS applied materials & interfaces, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Keying GuoMonash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia.
Maria AlbaMonash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia.ORCID https://orcid.org/0000-0003-2119-9082
Grace Pei ChinMonash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia.
Ziqiu TongMonash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia.ORCID https://orcid.org/0000-0003-4183-1858
Bin GuanFuture Industries Institute, University of South Australia, Mawson Lakes, South Australia 5095, Australia.ORCID https://orcid.org/0000-0003-1247-6914
Michael J SailorDepartment of Chemistry and Biochemistry and Department of Nanoengineering, University of California, San Diego, La Jolla, California 92093-0358, United States.ORCID https://orcid.org/0000-0002-4809-9826
Nicolas H VoelckerMonash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia.ORCID https://orcid.org/0000-0002-1536-7804
Beatriz Prieto-SimónDepartment of Electronic Engineering, Universitat Rovira i Virgili, Tarragona 43007, Spain.ORCID https://orcid.org/0000-0001-8016-1565

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Porous silicon (pSi) is an established porous material that offers ample opportunities for biosensor design thanks to its tunable structure, versatile surface chemistry, and large surface area. Nonetheless, its potential for electrochemical sensing is relatively unexplored. This study investigates layered carbon-stabilized pSi nanostructures with site-specific functionalities as an electrochemical biosensor. A double-layer nanostructure combining a top hydrophilic layer of thermally carbonized pSi (TCpSi) and a bottom hydrophobic layer of thermally hydrocarbonized pSi (THCpSi) is prepared. The modified layers are formed in a stepwise process, involving first an electrochemical anodization step to generate a porous layer with precisely defined pore morphological features, followed by deposition of a thin thermally carbonized coating on the pore walls via temperature-controlled acetylene decomposition. The second layer is then generated beneath the first by following the same two-step process, but the acetylene decomposition conditions are adjusted to deposit a thermally hydrocarbonized coating. The double-layer platform features excellent electrochemical properties such as fast electron-transfer kinetics, which underpin the performance of a TCpSi-THCpSi voltammetric DNA sensor. The biosensor targets a 28-nucleotide single-stranded DNA sequence with a detection limit of 0.4 pM, two orders of magnitude lower than the values reported to date by any other pSi-based electrochemical DNA sensor.

Indexed as

Biosensing TechniquesNanostructuresCarbonPorositySiliconCarbonSiliconcontrollable surface chemistrydual-surface functionalityelectrochemical biosensorlayered nanostructuresporous silicon

Identifiers

PMID35286082
PMCPMC9682479

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.