Target localization accuracy in frame-based stereotactic radiosurgery: Comparison between MR-only and MR/CT co-registration approaches.

Eleftherios P Pappas, Ioannis Seimenis, Panagiotis Kouris, Stefanos Theocharis, Kostas I Lampropoulos, Georgios Kollias, Pantelis Karaiskos

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Physics and imaging in radiation oncology · 2023
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Eleftherios P PappasMedical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece.
Ioannis SeimenisMedical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece.
Panagiotis KourisMedical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece.
Stefanos TheocharisMedical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece.
Kostas I LampropoulosMedical Physics and Gamma Knife Department, Hygeia Hospital, Marousi, Greece.
Georgios KolliasMedical Physics and Gamma Knife Department, Hygeia Hospital, Marousi, Greece.
Pantelis KaraiskosMedical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece.

Funding

Greece and the European Union (European Social Fund-ESF)
6 · The paper itself

Abstract

purposeIn frame-based Gamma Knife (GK) stereotactic radiosurgery two treatment planning workflows are commonly employed; one based solely on magnetic resonance (MR) images and the other based on magnetic resonance/computed tomography (MR/CT) co-registered images. In both workflows, target localization accuracy (TLA) can be deteriorated due to MR-related geometric distortions and/or MR/CT co-registration uncertainties. In this study, the overall TLA following both clinical workflows is evaluated for cases of multiple brain metastases.

methodsA polymer gel-filled head phantom, having the Leksell stereotactic headframe attached, was CT-imaged and irradiated by a GK Perfexion unit. A total of 26 4-mm shots were delivered at 26 locations directly defined in the Leksell stereotactic space (LSS), inducing adequate contrast in corresponding T2-weighted (T2w) MR images. Prescribed shot coordinates served as reference locations. An additional MR scan was acquired to implement the "mean image" distortion correction technique. The TLA for each workflow was assessed by comparing the radiation-induced target locations, identified in MR images, with corresponding reference locations. Using T1w MR and CT images of 15 patients (totaling 81 lesions), TLA in clinical cases was similarly assessed, considering MR-corrected data as reference. For the MR/CT workflow, both global and region of interest (ROI)-based MR/CT registration approaches were studied.

resultsIn phantom measurements, the MR-corrected workflow demonstrated unsurpassed TLA (median offset of 0.2 mm) which deteriorated for MR-only and MR/CT workflows (median offsets of 0.8 and 0.6 mm, respectively). In real-patient cases, the MR-only workflow resulted in offsets that exhibit a significant positive correlation with the distance from the MR isocenter, reaching 1.1 mm (median 0.6 mm). Comparable results were obtained for the MR/CT-global workflow, although a maximum offset of 1.4 mm was detected. TLA was improved with the MR/CT-ROI workflow resulting in median/maximum offsets of 0.4 mm/1.1 mm.

conclusionsSubpixel TLA is achievable in all workflows. For the MR/CT workflow, a ROI-based MR/CT co-registration approach could considerably increase TLA and should be preferred instead of a global registration.

Indexed as

RadiosurgeryHumansMagnetic Resonance ImagingMagnetic Resonance SpectroscopyPhantoms, ImagingTomography, X-Ray ComputeddistortionframeGamma Kniferegistrationspatial accuracySRSstereotactic space

Identifiers

PMID35285583
PMCPMC9121047

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.