Evidence map›Paper›PMID 35284662›Full record

ArticlePhysics and imaging in radiation oncology2022

Robust extraction of biological information from diffusion-weighted magnetic resonance imaging during radiotherapy using semi-automatic delineation.

Anne Louise Højmark Bisgaard, Carsten Brink, Maja Lynge Fransen, Tine Schytte, Claus P Behrens, Ivan Vogelius, Henrik Dahl Nissen, Faisal Mahmood

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Recommendations for improved reproducibility of ADC derivation on behalf of the Elekta MRI-linac consortium image analysis working group.Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2023
    Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Anne Louise Højmark BisgaardLaboratory of Radiation Physics, Department of Oncology, Odense University Hospital, Kløvervænget 19, Indgang 85, Pavillon, stuen, 5000 Odense C, Denmark.
Carsten BrinkLaboratory of Radiation Physics, Department of Oncology, Odense University Hospital, Kløvervænget 19, Indgang 85, Pavillon, stuen, 5000 Odense C, Denmark.
Maja Lynge FransenDepartment of Radiology, Odense University Hospital, Kløvervænget 47, Indgang 27, 5000 Odense C, Denmark.
Tine SchytteDepartment of Clinical Research, University of Southern Denmark, Winsløwparken 19, 3. Sal, 5000 Odense C, Denmark.
Claus P BehrensDepartment of Oncology, Herlev and Gentofte Hospital, Borgmester IB Juuls Vej 7, 2730 Herlev, Denmark.
Ivan VogeliusDepartment of Clinical Oncology, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark.
Henrik Dahl NissenDepartment of Oncology, Vejle Hospital, Beriderbakken 4, 7100 Vejle, Denmark.
Faisal MahmoodLaboratory of Radiation Physics, Department of Oncology, Odense University Hospital, Kløvervænget 19, Indgang 85, Pavillon, stuen, 5000 Odense C, Denmark.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purpose: Diffusion-Weighted Magnetic Resonance imaging (DWI) quantifies water mobility through the Apparent Diffusion Coefficient (ADC), a promising radiotherapy response biomarker. ADC measurements depend on manual delineation of a region of interest, a time-consuming and observer-dependent process. Here, the aim was to introduce and test the performance of a new, semi-automatic delineation tool (SADT) for ADC calculation within the viable region of the tumour. Materials and methods: Thirty patients with rectal cancer were scanned with DWI before radiotherapy (RT) (baseline) and two weeks into RT (week 2). The SADT was based on intensities in b=1100 s mm Results: ADC measured using the SADT and manual delineation showed strong and moderate correlation at baseline and week 2, respectively, with the SADT measuring systematically smaller values. Intra-observer ADC variation was slightly smaller for the SADT compared to manual delineation both at baseline, [-0.00; 0.03] vs. [-0.02; 0.04] 10 Conclusion: The presented SADT showed performance comparable to manual expert delineation, and with sufficient consistency to allow extraction of potential biological information from the viable tumour.

Indexed as

Apparent diffusion coefficientAutomatic delineationDiffusion-weighted MRIImaging biomarkerMRI guided radiotherapy