Evidence map›Paper›PMID 35280356›Full record

ArticleAnnals of translational medicine2022

Biomechanical study of extramedullary and intramedullary fixation in the treatment of unstable intertrochanteric reversed-tilt fractures of the femur.

Guo-Liang Lu, Song-Jun Li, Wen-Xue Li

Open access · diamondAbstract read
In one paragraph

Article in Annals of translational medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 5 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 1 country.

Guo-Liang Lu *Department of Orthopedic Trauma, Foshan Hospital of TCM (The Eighth Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine), Foshan, China.
Song-Jun Li *Department of Orthopedics, the Fifth Affiliated Hospital of Zunyi Medical University, Zhuhai, China.
Wen-Xue LiDepartment of Orthopedics, Dongying Hospital of Traditional Chinese Medicine, Dongying, China.
Dongyang People's Hospital · CNFoshan Hospital of TCM · CNZunyi Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: To investigate the efficacy of the 135° hip screw, 95° intramedullary hip screw (IMHS) and 95° hip screw in the treatment of intertrochanteric reverse dip fracture of the femur. Methods: We retrospectively analyzed 125 matched pairs of human femurs (median age 64 years) which were osteotomized at a 33° angle in the left femur and extended downward from the minor trochanter to simulate a reverse oblique intertrochanteric fracture. The right femur served as a control. The left femur (n=4) was implanted with a 135° hip screw, 95° hip screw, or IMHS. A strain detector was placed distal to the fracture site to monitor fragment strain. The lateral displacement of the proximal femur was measured by a linear variable differential transformer. An Instron tester measured stiffness, strain, and lateral displacement at 25° adduction, and 90° adduction with vertical loads on the femoral head. A 2 cm gap was then formed at the fracture site to simulate comminution and the mechanical test was repeated. Results: Before the formation of the gap, there was no significant difference in stiffness among different bone structures (P>0.05), but after the formation of the gap, the stiffness of all the adduction structures decreased (P=0.03), and the difference in adduction was statistically significant (135° hip screw: 46.6%±3%; 95° hip screw: 22.9%±2%; IMHS: 53.7%±7.8%; P<0.05). Similar results were found for the abduction and buckling positions. There was no significant difference in the lateral displacement of the gap before (P=0.92) and after (P=0.26), but a significant difference in the failure load was found (135° hip screw: 1,222±560 N; 95° hip screw: 2,566±283 N; IMHS: 4,644±518 N; P=0.02). Conclusions: There was no statistically significant difference in stiffness among different structures (P>0.05). However, in the presence of gaps, IMHS bone implant structures are much stiffer than 135° and 95° structures and have a greater destructive load.

Indexed as

biomechanicsHip screwintertrochanteric reverse dip fractureintramedullary nailretrospective study

Identifiers

PMID35280356
PMCPMC8908151
OpenAlexW4214618091

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.