ArticleJournal of chromatography. B, Analytical technologies in the biomedical and life sciences2022
UPLC-MS/MS method for the quantification of MCI-77, a novel sigma-1 receptor ligand, and its application to pharmacokinetic studies.
Article in Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 0 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
Abstract
Sigma-1 receptors are involved in pain modulation, particularly in cases of nerve injury and neuropathic pain. High-affinity ligands with improved pharmacokinetic profiles are needed to further investigate the properties of these receptors and their potential as a therapeutic target. The novel compound MCI-77 is one such selective sigma-1 receptor ligand, and the purpose of this study was to characterize its preclinical pharmacokinetic parameters. An ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated to quantify MCI-77 in mouse plasma and brain homogenate. The method was validated for sensitivity, selectivity, linearity, accuracy, precision, stability, and dilution integrity. The method has a linearity range of 2-200 ng/mL, a short run-time of 3.2 min, and requires a low sample volume of 25 µL. A simple protein precipitation procedure was used for compound extraction. Samples were run on an Acquity UPLC BEH C
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.