ArticleActa biomaterialia2022
Characterization of vaginal immune response to a polypropylene mesh: Diabetic vs. normoglycemic conditions.
Article in Acta biomaterialia, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 10 citations in OpenAlex.
- The developing field of meshology - what is new in the management of mesh complications in female incontinence and prolapse - a systematic review of outcomes.International journal of impotence research · 2026Review
- Article
- Delayed Vesicocutaneous Fistula 18 Years After Tension-Free Vaginal Tape: A Rare Case Report.International medical case reports journal · 2026Article
- Feasibility and Clinical Outcomes of Robot-Assisted Sacrocolpopexy Using Autologous Round Ligament Grafts: A Novel Non-Mesh Surgical Approach for Pelvic Organ Prolapse.Medicina (Kaunas, Lithuania) · 2025Article
- Cytokine modulation in pelvic organ prolapse and urinary incontinence: from molecular insights to therapeutic targets.Molecular medicine (Cambridge, Mass.) · 2024Review
- Dysregulated inflammatory response to urogynecologic meshes in women with diabetes and its implications.American journal of obstetrics and gynecology · 2024Article
- The use of animal models in preclinical investigations for the development of a surgical mesh for pelvic organ prolapse.International urogynecology journal · 2024Review
- The impact of diabetes mellitus on pelvic organ prolapse recurrence after robotic sacrocolpopexy.International urogynecology journal · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
objectiveUrogynecology meshes, typically manufactured from polypropylene, are widely used in the surgical treatment of stress urinary incontinence and pelvic organ prolapse. However, mesh-associated complications such as mesh exposure can develop in women undergoing mesh implantation, for which diabetes is an independent risk factor. We aimed to define the impact of diabetes on the vaginal immune response to mesh by comparing diabetic vs. normoglycemic conditions longitudinally in a rat sacrocolpopexy model.
methodsDiabetes (blood glucose ≥ 300 mg/dL) was induced in middle-aged female Wistar rats with streptozotocin (STZ). A polypropylene mesh was implanted on the vagina via modified sacrocolpopexy following bilateral ovariectomy and supracervical hysterectomy for 3-, 7-, and 42-days. Sham-operated controls underwent the same procedures without mesh. Mesh-associated inflammation, immune cell populations and cytokine/chemokine profiles were examined in the excised vaginal tissues.
resultsDiabetes was reliably induced starting on the 3rd day following STZ injection. Under both normoglycemic and diabetic conditions, mesh caused a prolonged inflammatory response in the vagina with increased proinflammatory chemokines MCP-1 and MIP-1α as compared to Sham. Major differences between the two conditions were found at the later stage (42 days post-surgery), including an increased inflammation with larger foreign body granuloma and more giant cells at the mesh-tissue interface, increased fraction of macrophages in the immune cell population, and higher proinflammatory chemokine IP-10 in the diabetic group.
conclusionPolypropylene mesh implanted on the vagina induces prolonged inflammation at the mesh-tissue interface. Diabetes increases the mesh-associated inflammation in the long term, which is related to a dysregulated macrophage response. STATEMENT OF SIGNIFICANCE: This study investigated the mechanism underlying the increased risk in women with diabetes for developing mesh complications such as mesh exposure. The significance includes: (1) it is the first study investigating vaginal host response to a prosthesis under the influence of diabetes; (2) the longitudinal study design elucidated the dynamic changes of vaginal immune response to mesh from very early to late stages; (3) our findings may inform future mechanistic studies and studies investigating preventive/therapeutic strategies to improve the outcomes of women with diabetes receiving vaginal implants.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.