First clinical experience with a novel, mobile cone-beam CT system for treatment quality assurance in brachytherapy.

Andre Karius, Vratislav Strnad, Michael Lotter, Stephan Kreppner, Christoph Bert

Open access · hybridAbstract read
In one paragraph

Article in Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al], 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
5.9field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Is model-based dose calculation based on cone-beam computed tomography suitable for adaptive treatment planning in brachytherapy?Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2025
    Article
  9. Article
  10. Article
  11. Investigating the impact of breast positioning control on physical treatment parameters in multi-catheter breast brachytherapy.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2024
    Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Andre KariusDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander Universität Erlangen-Nürnberg, Universitätsstr. 27, 91054, Erlangen, Germany. andre.karius@uk-erlangen.de.ORCID 0000-0002-3842-1375
Vratislav StrnadDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander Universität Erlangen-Nürnberg, Universitätsstr. 27, 91054, Erlangen, Germany.
Michael LotterDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander Universität Erlangen-Nürnberg, Universitätsstr. 27, 91054, Erlangen, Germany.
Stephan KreppnerDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander Universität Erlangen-Nürnberg, Universitätsstr. 27, 91054, Erlangen, Germany.
Christoph BertDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander Universität Erlangen-Nürnberg, Universitätsstr. 27, 91054, Erlangen, Germany.
Friedrich-Alexander-Universität Erlangen-Nürnberg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeOn-site cone-beam computed tomography (CBCT) has gained in importance in adaptive brachytherapy during recent years. Besides treatment planning, there is increased need particularly for image-guidance during interventional procedures and for image-guided treatment quality assurance (QA). For this purpose, an innovative CBCT device was rolled out at our hospital as the first site worldwide. We present the first clinical images and experiences. MATERIALS AND

methodsThe novel CBCT system is constructed of a 121 cm diameter ring gantry, and features a 43.2 × 43.2 cm

resultsWith the presented device, treatment QA was feasible for the majority of patients. The CBCT scans of breast patients showed sufficient contrast between implanted catheters and tissue. For gynecologic patients, a distinct visualization of applicators was achieved in general. However, reasonable differentiations of organic soft tissues were not feasible.

conclusionThe CBCT system allowed basic treatment QA measures for breast and gynecologic patients. For image-guidance during interventional brachytherapy procedures, the current image quality is not adequate. Substantial performance enhancements are required for intraoperative image-guidance.

Indexed as

BrachytherapyCone-Beam Computed TomographyFemaleHumansPhantoms, ImagingAdaptive brachytherapyGynecologic brachytherapyImage-guidanceMobile imagingOn-site computed tomography imaging

Identifiers

PMID35278094
PMCPMC9165284
OpenAlexW4220935696

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.