Evidence map›Paper›PMID 35275717›Full record

ArticleScience advances2022

Miniature coiled artificial muscle for wireless soft medical devices.

Mingtong Li, Yichao Tang, Ren Hao Soon, Bin Dong, Wenqi Hu, Metin Sitti

Abstract read
In one paragraph

Article in Science advances, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Bioinspired Twisted Artificial Muscles with Enhanced Performance for Underwater Applications.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  5. Article
  6. Physical Intelligence in Small-Scale Robots and Machines.Advanced materials (Deerfield Beach, Fla.) · 2026
    Review
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Fast, variable stiffness-induced braided coiled artificial muscles.Proceedings of the National Academy of Sciences of the United States of America · 2024
    Article
  15. Article
  16. Review
  17. Review
  18. Article
  19. Locally Addressable Energy Efficient Actuation of Magnetic Soft Actuator Array Systems.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mingtong LiPhysical Intelligence Department, Max Planck Institute for Intelligent Systems, 70569 Stuttgart, Germany.ORCID 0000-0002-1685-6052
Yichao TangPhysical Intelligence Department, Max Planck Institute for Intelligent Systems, 70569 Stuttgart, Germany.ORCID 0000-0002-6032-5558
Ren Hao SoonPhysical Intelligence Department, Max Planck Institute for Intelligent Systems, 70569 Stuttgart, Germany.ORCID 0000-0003-4188-540X
Bin DongInstitute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, Suzhou, Jiangsu 215123, P. R. China.
Wenqi HuPhysical Intelligence Department, Max Planck Institute for Intelligent Systems, 70569 Stuttgart, Germany.ORCID 0000-0002-3457-821X
Metin SittiPhysical Intelligence Department, Max Planck Institute for Intelligent Systems, 70569 Stuttgart, Germany.ORCID 0000-0001-8249-3854

Funding

European Research Council 834531
6 · The paper itself

Abstract

Wireless small-scale soft-bodied devices are capable of precise operation inside confined internal spaces, enabling various minimally invasive medical applications. However, such potential is constrained by the small output force and low work capacity of the current miniature soft actuators. To address this challenge, we report a small-scale soft actuator that harnesses the synergetic interactions between the coiled artificial muscle and radio frequency-magnetic heating. This wirelessly controlled actuator exhibits a large output force (~3.1 N) and high work capacity (3.5 J/g). Combining this actuator with different mechanical designs, its tensile and torsional behaviors can be engineered into different functional devices, such as a suture device, a pair of scissors, a driller, and a clamper. In addition, by assuming a spatially varying magnetization profile, a multilinked coiled muscle can have both magnetic field-induced bending and high contractile force. Such an approach could be used in various future untethered miniature medical devices.

Identifiers

PMID35275717
PMCPMC8916729

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.