Evidence map›Paper›PMID 35271618›Full record

ArticlePloS one2022

Cortical and medullary oxygenation evaluation of kidneys with renal artery stenosis by BOLD-MRI.

Long Zhao, Guoqi Li, Fanyu Meng, Zhonghua Sun, Jiayi Liu

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.9field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Kidney R2* Mapping for Noninvasive Evaluation of Iron Overload in Paroxysmal Nocturnal Hemoglobinuria.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2025
    Article
  3. Article
  4. Article
  5. Review
  6. BOLD MRI to Evaluate the Effects of Sacubitril/Valsartan on Renal Protection in Type 2 Diabetics.Diabetes, metabolic syndrome and obesity : targets and therapy · 2025
    Article
  7. Review
  8. Article
  9. Article
  10. Evaluation of a deuterated triarylmethyl spin probe for in vivobioRxiv : the preprint server for biology · 2023
    Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Long ZhaoDepartment of Radiology, Beijing Anzhen Hospital, Beijing, China.
Guoqi LiEnergy conservation and environmental protection division, Aerospace HIWING Security Technology Engineering Co., Ltd, Beijing, China.
Fanyu MengInternational Cooperation Office, Beijing Anzhen Hospital, Beijing, China.
Zhonghua SunDiscipline of Medical Radiation Science, Curtin Medical School, Curtin University, Perth, Australia.ORCID 0000-0002-7538-4761
Jiayi LiuDepartment of Radiology, Beijing Anzhen Hospital, Beijing, China.ORCID 0000-0002-5617-7054
Beijing Anzhen Hospital · CNCurtin University · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimBlood oxygen level-dependent magnetic resonance imaging (BOLD-MRI) can measure deoxyhemoglobin content. This study aims to evaluate the capacity of BOLD-MRI, which is possible to evaluate the oxygenation state of kidneys with renal artery stenosis (RAS). MATERIALS AND

methodsWe performed BOLD-MRI for 40 patients with RAS and for 30 healthy volunteers. We then performed post-scan processing and analysis of manually drawn regions of interest to determine R2* values (relaxation rates) for the renal cortex and medulla. We compared R2* values in patients with RAS with those in the control group, and also compared these values for subgroups with varying degrees of stenosis.

resultsMedulla R2* values were higher than cortex R2* values in the control group. There was no significant difference in R2* values for different segments (upper, middle, lower) of the kidneys. Both cortex and medulla R2* values in patients with RAS were significantly higher than corresponding R2* values in the control group (P < 0.05), and BOLD-MRI was more sensitive to changes in the R2* values in the medulla than in the cortex. Among different subgroups in the RAS group, the medulla R2* values were significantly higher in kidneys with severe stenosis than in those with no obvious obstruction, mild stenosis, or moderate stenosis (P < 0.05).

conclusionBOLD-MRI is an effective, noninvasive method for evaluating kidney oxygenation, which is important for proper treatment in RAS. It is sufficiently sensitive for detecting medulla ischemia and anoxia of the kidneys.

Indexed as

Renal Artery ObstructionConstriction, PathologicFemaleHumansKidneyMagnetic Resonance ImagingMaleOxygenOxygen

Identifiers

PMID35271618
PMCPMC8912187
OpenAlexW4220726170

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.