Evidence map›Paper›PMID 35271134›Full record

ArticleSensors (Basel, Switzerland)2022

Real-Time Internet of Medical Things System for Detecting Blood Leakage during Hemodialysis Using a Novel Multiple Concentric Ring Sensor.

Hsiang-Wei Hu, Chih-Hao Liu, Yi-Chun Du, Kuan-Yu Chen, Hsuan-Ming Lin, Chou-Ching Lin

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 5 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Hsiang-Wei HuDepartment of Biomedical Engineering, National Cheng Kung University, Tainan 704, Taiwan.
Chih-Hao LiuAcuSense BioMedical Technology Corp., Tainan 744, Taiwan.
Yi-Chun DuDepartment of Biomedical Engineering, National Cheng Kung University, Tainan 704, Taiwan.ORCID 0000-0002-6087-4610
Kuan-Yu ChenInternational Academia of Biomedical Innovation Technology, Taipei 104, Taiwan.
Hsuan-Ming LinDepartment of Nephrology, An Nan Hospital, China Medical University, Tainan 709, Taiwan.ORCID 0000-0001-8095-7870
Chou-Ching LinDepartment of Biomedical Engineering, National Cheng Kung University, Tainan 704, Taiwan.ORCID 0000-0002-3070-5787
National Cheng Kung University · TWChina Medical University · TWNational Cheng Kung University Hospital · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Venous needle dislodgement (VND) is a major healthcare safety concern in patients undergoing hemodialysis. Although VND is uncommon, it can be life-threatening. The main objective of this study was to implement a real-time multi-bed monitoring system for VND by combining a novel leakage-detection device and IoMT (Internet of Medical Things) technology. The core of the system, the Acusense IoMT platform, consisted of a novel leakage-detection patch comprised of multiple concentric rings to detect blood leakage and quantify the leaked volume. The performance of the leakage-detection system was evaluated on a prosthetic arm and clinical study. Patients with a high risk of blood leakage were recruited as candidates. The system was set up in a hospital, and the subjects were monitored for 2 months. During the pre-clinical simulation experiment, the system could detect blood leakage volumes from 0.3 to 0.9 mL. During the test of the IoMT system, the overall success rate of tests was 100%, with no lost data packets. A total of 701 dialysis sessions were analyzed, and the accuracy and sensitivity were 99.7% and 90.9%, respectively. Evaluation questionnaires showed that the use of the system after training changed attitudes and reduced worry of the nursing staff. Our results show the feasibility of using a novel detector combined with an IoMT system to automatically monitor multi-bed blood leakage. The innovative concentric-circle design could more precisely control the warning blood-leakage threshold in any direction to achieve clinical cost-effectiveness. The system reduced the load on medical staff and improved patient safety. In the future, it could also be applied to home hemodialysis for telemedicine during the era of COVID-19.

Indexed as

Artificial LimbsCOVID-19ArmHumansInternetRenal DialysisSARS-CoV-2blood leakage detectionhemodialysisInternet of Medical Things (IoMT)multi-bed monitoring systemvenous needle dislodgement

Identifiers

PMID35271134
PMCPMC8914681
OpenAlexW4214944066

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.