A Data-Driven Model with Feedback Calibration Embedded Blood Pressure Estimator Using Reflective Photoplethysmography.

Jia-Wei Chen, Hsin-Kai Huang, Yu-Ting Fang, Yen-Ting Lin, Shih-Zhang Li, Bo-Wei Chen, Yu-Chun Lo, Po-Chuan Chen, Ching-Fu Wang, You-Yin Chen

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 2 pooled it
1.1field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 2 syntheses or guidelines pooled it, 15 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 5 institutions in 2 countries.

Jia-Wei ChenDepartment of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan.
Hsin-Kai HuangDepartment of Cardiology, Ten-Chan General Hospital (Chung Li), Taoyuan 32043, Taiwan.
Yu-Ting FangDepartment of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan.
Yen-Ting LinDepartment of Internal Medicine, Taoyuan General Hospital, Ministry of Health and Welfare, Taoyuan 33004, Taiwan.
Shih-Zhang LiDepartment of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan.
Bo-Wei ChenDepartment of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan.
Yu-Chun LoThe Ph.D. Program for Neural Regenerative Medicine, Taipei Medical University, Taipei 11031, Taiwan.
Po-Chuan ChenSchool of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.
Ching-Fu WangDepartment of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan.ORCID 0000-0001-5874-6591
You-Yin ChenDepartment of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan.ORCID 0000-0003-4869-3857
National Yang Ming Chiao Tung University · TWGeorgia Institute of Technology · USMinistry of Health and Welfare · TWTaipei Medical University · TWTen Chen Hospital · TW

Funding

Ministry of Science and Technology of Taiwan 109-2221-E-010-004-MY2Ministry of Science and Technology of Taiwan 110-2622-E-A49A-501Taoyuan General Hospital National Yang Ming University Joint Research Program TYGH-NYMU PTH10537
6 · The paper itself

Abstract

Ambulatory blood pressure (BP) monitoring (ABPM) is vital for screening cardiovascular activity. The American College of Cardiology/American Heart Association guideline for the prevention, detection, evaluation, and management of BP in adults recommends measuring BP outside the office setting using daytime ABPM. The recommendation to use night-day BP measurements to confirm hypertension is consistent with the recommendation of several other guidelines. In recent studies, ABPM was used to measure BP at regular intervals, and it reduces the effect of the environment on BP. Out-of-office measurements are highly recommended by almost all hypertension organizations. However, traditional ABPM devices based on the oscillometric technique usually interrupt sleep. For all-day ABPM purposes, a photoplethysmography (PPG)-based wrist-type device has been developed as a convenient tool. This optical, noninvasive device estimates BP using morphological characteristics from PPG waveforms. As measurement can be affected by multiple variables, calibration is necessary to ensure that the calculated BP values are accurate. However, few studies focused on adaptive calibration. A novel adaptive calibration model, which is data-driven and embedded in a wearable device, was proposed. The features from a 15 s PPG waveform and personal information were input for estimation of BP values and our data-driven calibration model. The model had a feedback calibration process using the exponential Gaussian process regression method to calibrate BP values and avoid inter- and intra-subject variability, ensuring accuracy in long-term ABPM. The estimation error of BP (ΔBP = actual BP-estimated BP) of systolic BP was -0.1776 ± 4.7361 mmHg; ≤15 mmHg, 99.225%, and of diastolic BP was -0.3846 ± 6.3688 mmHg; ≤15 mmHg, 98.191%. The success rate was improved, and the results corresponded to the Association for the Advancement of Medical Instrumentation standard and British Hypertension Society Grading criteria for medical regulation. Using machine learning with a feedback calibration model could be used to assess ABPM for clinical purposes.

Indexed as

Blood Pressure Monitoring, AmbulatoryPhotoplethysmographyAdultBlood PressureCalibrationFeedbackHumansUnited Statesblood pressureGaussian process regressionmachine learningphotoplethysmographywearable devices

Identifiers

PMID35271020
PMCPMC8914760
OpenAlexW4214525881

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.