Evidence map›Paper›PMID 35270942›Full record

ArticleSensors (Basel, Switzerland)2022

Fibre Bragg Grating Based Interface Pressure Sensor for Compression Therapy.

James A Bradbury, Qimei Zhang, Francisco U Hernandez Ledezma, Ricardo Correia, Serhiy Korposh, Barrie R Hayes-Gill, Ferdinand Tamoué, Alison Parnham, Simon A McMaster, Stephen P Morgan

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.6field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Observational
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 2 countries.

James A BradburyOptics and Photonics Group, Faculty of Engineering, University of Nottingham, Nottingham NG7 2RD, UK.ORCID 0000-0002-7083-0670
Qimei ZhangDepartment of Engineering, School of Science and Technology, Nottingham Trent University Nottingham, Nottingham NG1 4FQ, UK.ORCID 0000-0001-5811-8034
Francisco U Hernandez LedezmaFootfalls and Heartbeats (UK) Limited, 10 Castle Quay, Castle Boulevard, Nottingham NG7 1FW, UK.ORCID 0000-0003-4460-7405
Ricardo CorreiaOptics and Photonics Group, Faculty of Engineering, University of Nottingham, Nottingham NG7 2RD, UK.ORCID 0000-0001-6405-5340
Serhiy KorposhOptics and Photonics Group, Faculty of Engineering, University of Nottingham, Nottingham NG7 2RD, UK.ORCID 0000-0001-5179-6991
Barrie R Hayes-GillOptics and Photonics Group, Faculty of Engineering, University of Nottingham, Nottingham NG7 2RD, UK.ORCID 0000-0003-4237-7001
Ferdinand TamouéKOB GmbH, Lauterstraße 50, 67752 Wolfstein, Germany.
Alison ParnhamSchool of Health Sciences, University of Nottingham, Nottingham NG7 2RD, UK.
Simon A McMasterFootfalls and Heartbeats (UK) Limited, 10 Castle Quay, Castle Boulevard, Nottingham NG7 1FW, UK.
Stephen P MorganOptics and Photonics Group, Faculty of Engineering, University of Nottingham, Nottingham NG7 2RD, UK.ORCID 0000-0003-4069-3801
University of Nottingham · GBKOB (Germany) · DENottingham Trent University · GB

Funding

Engineering and Physical Sciences Research Council EP/K503800/1
6 · The paper itself

Abstract

Compression therapy is widely used as the gold standard for management of chronic venous insufficiency and venous leg ulcers, and the amount of pressure applied during the compression therapy is crucial in supporting healing. A fibre optic pressure sensor using Fibre Bragg Gratings (FBGs) is developed in this paper to measure sub-bandage pressure whilst removing cross-sensitivity due to strain in the fibre and temperature. The interface pressure is measured by an FBG encapsulated in a polymer and housed in a textile to minimise discomfort for the patient. The repeatability of a manual fabrication process is investigated by fabricating and calibrating ten sensors. A customized calibration setup consisting of a programmable translation stage and a weighing scale gives sensitivities in the range 0.4-1.5 pm/mmHg (2.6-11.3 pm/kPa). An alternative calibration method using a rigid plastic cylinder and a blood pressure cuff is also demonstrated. Investigations are performed with the sensor under a compression bandage on a phantom leg to test the response of the sensor to changing pressures in static situations. Measurements are taken on a human subject to demonstrate changes in interface pressure under a compression bandage during motion to mimic a clinical application. These results are compared to the current gold standard medical sensor using a Bland-Altman analysis, with a median bias ranging from -4.6 to -20.4 mmHg, upper limit of agreement (LOA) from -13.5 to 2.7 mmHg and lower LOA from -32.4 to -7.7 mmHg. The sensor has the potential to be used as a training tool for nurses and can be left in situ to monitor bandage pressure during compression therapy.

Indexed as

Compression BandagesVaricose UlcerCalibrationHumansTemperatureWound Healingcompression therapyFibre Bragg Gratingoptical fibre sensorsub-bandage pressure sensorvenous leg ulcer

Identifiers

PMID35270942
PMCPMC8915074
OpenAlexW4214501054

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked