Evidence map›Paper›PMID 35269268›Full record

ArticleNanomaterials (Basel, Switzerland)2022

A Biocompatible Ultrananocrystalline Diamond (UNCD) Coating for a New Generation of Dental Implants.

Orlando Auciello, Sandra Renou, Karam Kang, Deborah Tasat, Daniel Olmedo

Open access · goldAbstract read
In one paragraph

Article in Nanomaterials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 25 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Review
  6. Article
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 3 countries.

Orlando AucielloDepartment of Materials Science and Engineering and Bioengineering, Original Biomedical Implants (OBI-USA), University of Texas at Dallas, Dallas, TX 75080, USA.
Sandra RenouCátedra de Anatomía Patológica, Facultad de Odontología, Universidad de Buenos Aires, Buenos Aires C1122AAH, Argentina.ORCID 0000-0001-7907-6152
Karam KangHoefer Welker, Dallas, TX 75201, USA.
Deborah TasatCátedra de Histología y Embriología, Facultad de Odontología, Universidad de Buenos Aires, Buenos Aires C1122AAH, Argentina.ORCID 0000-0002-8087-7579
Daniel OlmedoCátedra de Anatomía Patológica, Facultad de Odontología, Universidad de Buenos Aires, Buenos Aires C1122AAH, Argentina.ORCID 0000-0002-2084-6973
Consejo Nacional de Investigaciones Científicas y Técnicas · ARInstituto Tecnológico de Hermosillo · MXKALGEn Consultants (United States) · USUniversidad de Buenos Aires · AR

Funding

School of Dentistry of the University of Buenos Aires FOUBA Res. (CD) N°330/19-01University of Buenos Aires UBACyT 20020190100148BAUniversity of Texas at Dallas Distinguished Endowed Chair Professor position
6 · The paper itself

Abstract

Implant therapy using osseointegratable titanium (Ti) dental implants has revolutionized clinical dental practice and has shown a high rate of success. However, because a metallic implant is in contact with body tissues and fluids in vivo, ions/particles can be released into the biological milieu as a result of corrosion or biotribocorrosion. Ultrananocrystalline diamond (UNCD) coatings possess a synergistic combination of mechanical, tribological, and chemical properties, which makes UNCD highly biocompatible. In addition, because the UNCD coating is made of carbon (C), a component of human DNA, cells, and molecules, it is potentially a highly biocompatible coating for medical implant devices. The aim of the present research was to evaluate tissue response to UNCD-coated titanium micro-implants using a murine model designed to evaluate biocompatibility. Non-coated (n = 10) and UNCD-coated (n = 10) orthodontic Ti micro-implants were placed in the hematopoietic bone marrow of the tibia of male Wistar rats. The animals were euthanized 30 days post implantation. The tibiae were resected, and ground histologic sections were obtained and stained with toluidine blue. Histologically, both groups showed lamellar bone tissue in contact with the implants (osseointegration). No inflammatory or multinucleated giant cells were observed. Histomorphometric evaluation showed no statistically significant differences in the percentage of BIC between groups (C: 53.40 ± 13% vs. UNCD: 58.82 ± 9%, p > 0.05). UNCD showed good biocompatibility properties. Although the percentage of BIC (osseointegration) was similar in UNCD-coated and control Ti micro-implants, the documented tribological properties of UNCD make it a superior implant coating material. Given the current surge in the use of nano-coatings, nanofilms, and nanostructured surfaces to enhance the biocompatibility of biomedical implants, the results of the present study contribute valuable data for the manufacture of UNCD coatings as a new generation of superior dental implants.

Indexed as

biocompatibilitybiotribocorrosionosseointegrationsurface treatmenttitanium micro-implantsultrananocrystalline diamond (UNCD) coating

Identifiers

PMID35269268
PMCPMC8911871
OpenAlexW4214684820

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.