Evidence map›Paper›PMID 35267844›Full record

ArticlePolymers2022

Oxygen Gas Sensing Using a Hydrogel-Based Organic Electrochemical Transistor for Work Safety Applications.

Francesco Decataldo, Filippo Bonafè, Federica Mariani, Martina Serafini, Marta Tessarolo, Isacco Gualandi, Erika Scavetta, Beatrice Fraboni

Open access · goldAbstract read
In one paragraph

Article in Polymers, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.6field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 21 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Francesco DecataldoDepartment of Physics and Astronomy, Alma Mater Studiorum-University of Bologna, Viale Berti Pichat 6/2, 40127 Bologna, Italy.ORCID 0000-0002-0669-7369
Filippo BonafèDepartment of Physics and Astronomy, Alma Mater Studiorum-University of Bologna, Viale Berti Pichat 6/2, 40127 Bologna, Italy.ORCID 0000-0003-2932-9099
Federica MarianiDepartment of Industrial Chemistry, Alma Mater Studiorum-University of Bologna, Viale Risorgimento 4, 40136 Bologna, Italy.ORCID 0000-0001-6293-3920
Martina SerafiniDepartment of Industrial Chemistry, Alma Mater Studiorum-University of Bologna, Viale Risorgimento 4, 40136 Bologna, Italy.ORCID 0000-0002-4776-5719
Marta TessaroloDepartment of Physics and Astronomy, Alma Mater Studiorum-University of Bologna, Viale Berti Pichat 6/2, 40127 Bologna, Italy.ORCID 0000-0003-0321-519X
Isacco GualandiDepartment of Industrial Chemistry, Alma Mater Studiorum-University of Bologna, Viale Risorgimento 4, 40136 Bologna, Italy.ORCID 0000-0002-6823-7501
Erika ScavettaDepartment of Industrial Chemistry, Alma Mater Studiorum-University of Bologna, Viale Risorgimento 4, 40136 Bologna, Italy.
Beatrice FraboniDepartment of Physics and Astronomy, Alma Mater Studiorum-University of Bologna, Viale Berti Pichat 6/2, 40127 Bologna, Italy.
University of Bologna · IT

Funding

European Union FESR FSE, PON Research and Innovation 2014-2020 and FSC ARS01-00996
6 · The paper itself

Abstract

Oxygen depletion in confined spaces represents one of the most serious and underestimated dangers for workers. Despite the existence of several commercially available and widely used gas oxygen sensors, injuries and deaths from reduced oxygen levels are still more common than for other hazardous gases. Here, we present hydrogel-based organic electrochemical transistors (OECTs) made with the conducting polymer poly(3,4-ethylenedioxythiophene): poly(styrene sulfonate) (PEDOT:PSS) as wearable and real-time oxygen gas sensors. After comparing OECT performances using liquid and hydrogel electrolytes, we identified the best PEDOT:PSS active layer and hydrogel coating (30 µm) combination for sensing oxygen in the concentration range of 13−21% (v/v), critical for work safety applications. The fast O2 solubilization in the hydrogel allowed for gaseous oxygen transduction in an electrical signal thanks to the electrocatalytic activity of PEDOT:PSS, while OECT architecture amplified the response (gain ~ 104). OECTs proved to have comparable sensitivities if fabricated on glass and thin plastic substrates, (−12.2 ± 0.6) and (−15.4 ± 0.4) µA/dec, respectively, with low power consumption (<40 µW). Sample bending does not influence the device response, demonstrating that our real-time conformable and lightweight sensor could be implemented as a wearable, noninvasive safety tool for operators working in potentially hazardous confined spaces.

Indexed as

hydrogelorganic electrochemical transistoroxygen sensorPEDOT:PSSwork safety

Identifiers

PMID35267844
PMCPMC8912781
OpenAlexW4214814608

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.