A comparison of manual electrocardiographic interval and waveform analysis in lead 1 of 12-lead ECG and Apple Watch ECG: A validation study.

Nabeel Saghir, Arjun Aggarwal, Nisha Soneji, Victoria Valencia, George Rodgers, Thomas Kurian

Open access · goldAbstract read
In one paragraph

Article in Cardiovascular digital health journal. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed
2.7field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed, 41 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Review
  17. Article
  18. Article
  19. Smart devices to measure and monitor QT intervals.Frontiers in cardiovascular medicine · 2023
    Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Nabeel SaghirDell Medical School at The University of Texas at Austin, Austin, Texas - Department of Internal Medicine.
Arjun AggarwalDell Medical School at The University of Texas at Austin, Austin, Texas - Department of Internal Medicine.
Nisha SonejiDell Medical School at The University of Texas at Austin, Austin, Texas - Department of Internal Medicine.
Victoria ValenciaDell Medical School at The University of Texas at Austin, Austin, Texas - Department of Internal Medicine.
George RodgersDell Medical School at The University of Texas at Austin, Austin, Texas - Department of Internal Medicine.
Thomas KurianDell Medical School at The University of Texas at Austin, Austin, Texas - Department of Internal Medicine.
The University of Texas at Austin · USSeton Medical Center Austin · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The Apple Watch Series 4 (AW) can detect atrial fibrillation and perform a single-lead electrocardiogram (ECG), but the clinical accuracy of AW ECG waveforms compared to lead 1 of a 12-lead ECG is unclear. Objective: The purpose of this study was to assess the accuracy of interval measurements on AW ECG tracings in comparison to lead 1 on a 12-lead ECG. Methods: We obtained ECGs at a university hospital of healthy volunteers age >18 years. ECG waveforms were measured with calipers to the nearest 0.25 mm. When possible, 3 consecutive waveforms in lead 1 were measured. Waveform properties, including intervals, were recorded. Concordance correlation coefficients and Bland-Altman plots were used to assess level of agreement between devices. Results: Twelve-lead (n = 113) and AW (n = 129) ECG waveforms from 43 volunteers (mean age 31 years; 65% female) were analyzed. Sinus rhythm interpretation between devices was 100% concordant. No arrhythmias were recorded. Mean difference (d) for heart rate was 1.16 ± 4.33 bpm (r = 0.94); 3.83 ± 113.54 ms for RR interval (r = 0.79); 5.43 ± 17 ms for PR interval (r = 0.83); -6.89 ± 14.81 ms for QRS interval (r = 0.65); -11.27 ± 22.9 ms for QT interval (r = 0.79); and -11.67 ± 27 ms for QTc interval (r = 0.57). There was moderate (d <40 ms) to strong (d <20 ms or < 5 bpm) agreement between devices represented by Bland-Altman plots. Conclusion: The AW produces accurate ECGs in healthy adults with moderate to strong agreement of basic ECG intervals.

Indexed as

AppleApple watchAtrial fibrillationECG interval: ECG monitoringKardiaLead 1PhotoplethysmographySmartwatchWearable

Identifiers

PMID35265871
PMCPMC8890353
OpenAlexW3081053603

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.