Evidence map›Paper›PMID 35265659›Full record

ArticleFrontiers in surgery2021

Evaluation of 3D Robotic-Guided Exoscopic Visualization in Microneurosurgery.

Naureen Keric, Harald Krenzlin, Elena Kurz, Dominik M A Wesp, Darius Kalasauskas, Florian Ringel

Abstract read
In one paragraph

Article in Frontiers in surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Naureen KericDepartment of Neurosurgery, University Medical Center, Johannes Gutenberg University of Mainz, Mainz, Germany.
Harald KrenzlinDepartment of Neurosurgery, University Medical Center, Johannes Gutenberg University of Mainz, Mainz, Germany.
Elena KurzDepartment of Neurosurgery, University Medical Center, Johannes Gutenberg University of Mainz, Mainz, Germany.
Dominik M A WespDepartment of Neurosurgery, University Medical Center, Johannes Gutenberg University of Mainz, Mainz, Germany.
Darius KalasauskasDepartment of Neurosurgery, University Medical Center, Johannes Gutenberg University of Mainz, Mainz, Germany.
Florian RingelDepartment of Neurosurgery, University Medical Center, Johannes Gutenberg University of Mainz, Mainz, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: The three-dimensional (3D) exoscope is a novel apparatus introduced in recent years. Although an operating microscope (OM) is customarily used, this novel application offers several advantages. Therefore, this study aimed to determine the feasibility of deploying a robotic-guided 3D-exoscope for microneurosurgery and gauge its subsequent performance. Methods: The use of a 3D exoscope was compared with that of OM during 16 surgical procedures. Postoperatively, surgeons completed an eight-item Likert-scale satisfaction survey. As a second step, a predefined surgical task was then undertaken by surgeons with varying levels of experience, assessing the time entailed. Two questionnaires, the satisfaction survey and NASA task load index (NASA-TLX), were administered. Results: During routine procedures, the exoscope proved superior in magnification and ergonomic maintenance, showing inferior image contrast, quality, and illumination. It again ranked higher in magnification and ergonomic maintenance during the suturing task, and the OM excelled in treatment satisfaction and stereoscopic orientation. Workload assessment using the NASA-TLX revealed no difference by modality in the pairwise analysis of all components. At varying levels of experience, beginners bear a significantly higher burden in all principle components than mid-level and expert participants ( Conclusion: The quality of visualization by 3D exoscope seems adequate for treatment and its ergonomic benefit is superior to that of OM. Although experienced surgeons performed a surgical simulation faster under the OM, no difference was evident in NASA-TLX surveys. The 3D exoscope is an excellent alternative to the OM.

Indexed as

5-ALAmicroscopeNASA Task Load Indexrobotic 3D exoscopesurgical performance

Identifiers

PMID35265659
PMCPMC8900219

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.