Evidence map›Paper›PMID 35265348›Full record

ArticleSovremennye tekhnologii v meditsine2021

Individual Navigation Templates for Subcortical Screw Placement in Lumbar Spine.

R A Kovalenko, V A Kashin, V Yu Cherebillo

Open access · diamondAbstract read
In one paragraph

Article in Sovremennye tekhnologii v meditsine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 2 pooled it
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 2 syntheses or guidelines pooled it, 7 citations in OpenAlex.

  1. Digital Twins and Health Care: an Umbrella Review.Journal of medical systems · 2025
    Pooled it
  2. Pooled it
  3. Review
  4. Review
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

R A KovalenkoAssistant, Department of Neurosurgery Pavlov First Saint Petersburg State Medical University, 6-8 L'va Tolstogo St., Saint Petersburg, 197022, Russia.
V A KashinPhD Student, Department of Neurosurgery Pavlov First Saint Petersburg State Medical University, 6-8 L'va Tolstogo St., Saint Petersburg, 197022, Russia.
V Yu CherebilloProfessor, Head of the Department of Neurosurgery Pavlov First Saint Petersburg State Medical University, 6-8 L'va Tolstogo St., Saint Petersburg, 197022, Russia.
First Pavlov State Medical University of St. Petersburg · RU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Subcortical screw placement is currently performed using frontal view fluoroscopy or intraoperative O-arm navigation system. The emergence of a novel technique for spinal navigation based on individual navigation templates created using 3D printing technology determines the need to study their safety and effectiveness in subcortical implantation. Materials and Methods: The study was based on the analysis of treatment results in 39 patients who underwent surgery with subcortical implantation of 130 screws using the MidLIF technique. In group 1, navigation templates were used, in group 2 - intraoperative fluoroscopic control. Comparative analysis of implantation correctness and time, the total operation time, and radiation load was performed. Results: The mean distance between the screw and the cortical plate recorded in the groups ranged within 1.20-3.97 mm, without statistically significant difference (p>0.05). The mean time of pedicle screw implantation was 137.0 [115.25; 161.50] s in group 1 and 314.0 [183.50; 403.25] s in group 2. The total operation time was reduced from 173.0 [155.0; 192.25] min in group 2 to 119.0 [108.0; 128.75] min in group 1. The average of 1.0 [1.0; 2.0] X-ray image was performed to place one screw in group 1, while it was 12.0 [10.0; 13.25] in group 2. The differences between the groups in terms of implantation time and radiation load were statistically significant (p<0.05). Conclusion: Compared with intraoperative fluoroscopy, the use of individual navigation templates for subcortical implantation of pedicle screws provides their correct positioning with a significant reduction in both operation time and radiation load at similar safety.

Indexed as

Pedicle ScrewsSurgery, Computer-AssistedHumansImaging, Three-DimensionalLumbar VertebraeTomography, X-Ray Computed3D printingnavigation guidenavigation templatesubcortical trajectory

Identifiers

PMID35265348
PMCPMC8858410
OpenAlexW3209836154