Evidence map›Paper›PMID 35265237›Full record

ArticleRadiology case reports2022

Pitfall for systemic artery aneurysms evaluation using electrocardiogram-gated subtracted three-dimensional fast spin echo sequence of magnetic resonance imaging in patients with Kawasaki disease.

Haruki Nonaka, Takanori Masuda, Masami Yoneyama, Masahiro Tahara, Mio Okano, Yuko Morikawa, Kazuya Sanada, Tomoyasu Sato

Open access · goldAbstract readCase Reports
In one paragraph

Article in Radiology case reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 51% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Haruki NonakaDepartment of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan.
Takanori MasudaDepartment of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki, Okayama, Japan.
Masami YoneyamaPhilips Japan, Tokyo, Japan.
Masahiro TaharaDepartment of Pediatric Cardiology, Tsuchiya General Hospital, Hiroshima, Japan.
Mio OkanoDepartment of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan.
Yuko MorikawaDepartment of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan.
Kazuya SanadaDepartment of Pediatric Cardiology, Tsuchiya General Hospital, Hiroshima, Japan.
Tomoyasu SatoDepartment of Diagnostic Radiology, Tsuchiya General Hospital, Hiroshima, Japan.
Hiroshima General Hospital · JPKawasaki University of Medical Welfare · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Kawasaki disease (KD) is described as a syndrome that causes both coronary and systemic artery aneurysms (SAAs). This report describes the pitfall for SAAs' evaluation when using electrocardiogram (ECG)-gated subtracted three-dimensional fast spin echo (3D FSE) sequence of magnetic resonance imaging in KD patients. A 12-year-old male was diagnosed with KD at 3 months of age. We acquired ECG-gated 3D FSE images in the diastole and systole phases with coronal sections. Subtraction was then performed from diastolic phase imaging to systolic phase imaging. A 15.5 mm right axillary artery aneurysm and an 8.0 mm left axillary artery aneurysm were identified with ECG-gated 3D FSE in the diastolic phase. However, we observed signal loss in the right axillary artery aneurysm when subtraction was performed to selectively detect arteries; further, the brachial artery was poorly detected. ECG-gated subtracted 3D FSE sequence of magnetic resonance imaging can compromise the image quality of both aneurysm and peripheral artery images when detecting SAAs.

Indexed as

Electrocardiogram-gated subtracted three-dimensional fast spin echoKawasaki diseaseMagnetic resonance imagingNon-contrast magnetic resonance angiographySystemic artery aneurysms

Identifiers

PMID35265237
PMCPMC8899111
OpenAlexW4214951814

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.