ArticleFrontiers in neurorobotics2022
Intention Detection Strategies for Robotic Upper-Limb Orthoses: A Scoping Review Considering Usability, Daily Life Application, and User Evaluation.
Article in Frontiers in neurorobotics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 1 synthesis or guideline pooled it, 42 citations in OpenAlex.
- Intention Prediction for Active Upper-Limb Exoskeletons in Industrial Applications: A Systematic Literature Review.Sensors (Basel, Switzerland) · 2025Pooled it
- Feasibility of post-stroke hand rehabilitation supported by a soft robotic hand orthosis in-clinic and at-home.Journal of neuroengineering and rehabilitation · 2025Trial
- Supporting upper limb movements with a soft robot after a brachial plexus injury.Nature communications · 2026Article
- sEMG-Based Motion Intention Recognition for Interactive Upper Limb Nursing Assistance.Sensors (Basel, Switzerland) · 2026Article
- Soft Robotics in Upper Limb Neurorehabilitation and Assistance: Current Clinical Evidence and Recommendations.Soft robotics · 2025Review
- Towards a validated glossary of usability attributes for the evaluation of wearable robotic devices.Journal of neuroengineering and rehabilitation · 2024Article
- Mixed methods usability evaluation of an assistive wearable robotic hand orthosis for people with spinal cord injury.Journal of neuroengineering and rehabilitation · 2023Article
- A hierarchical dynamic Bayesian learning network for EMG-based early prediction of voluntary movement intention.Scientific reports · 2023Article
- Interaction with a Hand Rehabilitation Exoskeleton in EMG-Driven Bilateral Therapy: Influence of Visual Biofeedback on the Users' Performance.Sensors (Basel, Switzerland) · 2023Article
- Design and validation of a novel online platform to support the usability evaluation of wearable robotic devices.Wearable technologies · 2023Article
- A modular, deep learning-based holistic intent sensing system tested with Parkinson's disease patients and controls.Frontiers in neurology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Wearable robotic upper limb orthoses (ULO) are promising tools to assist or enhance the upper-limb function of their users. While the functionality of these devices has continuously increased, the robust and reliable detection of the user's intention to control the available degrees of freedom remains a major challenge and a barrier for acceptance. As the information interface between device and user, the intention detection strategy (IDS) has a crucial impact on the usability of the overall device. Yet, this aspect and the impact it has on the device usability is only rarely evaluated with respect to the context of use of ULO. A scoping literature review was conducted to identify non-invasive IDS applied to ULO that have been evaluated with human participants, with a specific focus on evaluation methods and findings related to functionality and usability and their appropriateness for specific contexts of use in daily life. A total of 93 studies were identified, describing 29 different IDS that are summarized and classified according to a four-level classification scheme. The predominant user input signal associated with the described IDS was electromyography (35.6%), followed by manual triggers such as buttons, touchscreens or joysticks (16.7%), as well as isometric force generated by residual movement in upper-limb segments (15.1%). We identify and discuss the strengths and weaknesses of IDS with respect to specific contexts of use and highlight a trade-off between performance and complexity in selecting an optimal IDS. Investigating evaluation practices to study the usability of IDS, the included studies revealed that, primarily, objective and quantitative usability attributes related to effectiveness or efficiency were assessed. Further, it underlined the lack of a systematic way to determine whether the usability of an IDS is sufficiently high to be appropriate for use in daily life applications. This work highlights the importance of a user- and application-specific selection and evaluation of non-invasive IDS for ULO. For technology developers in the field, it further provides recommendations on the selection process of IDS as well as to the design of corresponding evaluation protocols.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.