Evidence map›Paper›PMID 35264922›Full record

ArticleFrontiers in neuroscience2022

OPRA-RS: A Hearing-Aid Fitting Method Based on Automatic Speech Recognition and Random Search.

Libio Gonçalves Braz, Lionel Fontan, Julien Pinquier, Michael A Stone, Christian Füllgrabe

Erratum issuedOpen access · goldAbstract read
In one paragraph

Article in Frontiers in neuroscience, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.8field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Libio Gonçalves BrazIRIT, CNRS, Université Paul Sabatier, Toulouse, France.
Lionel FontanArchean LABS, Montauban, France.
Julien PinquierIRIT, CNRS, Université Paul Sabatier, Toulouse, France.
Michael A StoneManchester Centre for Audiology and Deafness, School of Health Sciences, University of Manchester, Manchester, United Kingdom.
Christian FüllgrabeSchool of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, United Kingdom.
Centre National de la Recherche Scientifique · FRLoughborough University · GBManchester Academic Health Science Centre · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Hearing-aid (HA) prescription rules (such as NAL-NL2, DSL-v5, and CAM2) are used by HA audiologists to define initial HA settings (e.g., insertion gains, IGs) for patients. This initial fitting is later individually adjusted for each patient to improve clinical outcomes in terms of speech intelligibility and listening comfort. During this fine-tuning stage, speech-intelligibility tests are often carried out with the patient to assess the benefits associated with different HA settings. As these tests tend to be time-consuming and performance on them depends on the patient's level of fatigue and familiarity with the test material, only a limited number of HA settings can be explored. Consequently, it is likely that a suboptimal fitting is used for the patient. Recent studies have shown that automatic speech recognition (ASR) can be used to predict the effects of IGs on speech intelligibility for patients with age-related hearing loss (ARHL). The aim of the present study was to extend this approach by optimizing, in addition to IGs, compression thresholds (CTs). However, increasing the number of parameters to be fitted increases exponentially the number of configurations to be assessed. To limit the number of HA settings to be tested, three random-search (RS) genetic algorithms were used. The resulting new HA fitting method, combining ASR and RS, is referred to as "objective prescription rule based on ASR and random search" (OPRA-RS). Optimal HA settings were computed for 12 audiograms, representing average and individual audiometric profiles typical for various levels of ARHL severity, and associated ASR performances were compared to those obtained with the settings recommended by CAM2. Each RS algorithm was run twice to assess its reliability. For all RS algorithms, ASR scores obtained with OPRA-RS were significantly higher than those associated with CAM2. Each RS algorithm converged on similar optimal HA settings across repetitions. However, significant differences were observed between RS algorithms in terms of maximum ASR performance and processing costs. These promising results open the way to the use of ASR and RS algorithms for the fine-tuning of HAs with potential speech-intelligibility benefits for the patient.

Indexed as

age-related hearing loss (ARHL)automatic speech recognition (ASR)compression thresholdshearing aids (HAs)insertion gainsprescription rulerandom search (RS)

Identifiers

PMID35264922
PMCPMC8899657
OpenAlexW4213043933