Evidence map›Paper›PMID 35263407›Full record

ArticleRomanian journal of morphology and embryology = Revue roumaine de morphologie et embryologie

In vitro study of the orthodontic mini-implants influence on the growth of human osteoblasts.

Andreea Moldoveanu, Mihnea Ioan Nicolescu, Mirela Veronica Bucur, George Gabriel Moldoveanu, Cristian Funieru, Ionela Victoria Neagoe, Gina Manda, Tamara Rahela Ioana, Lucian Toma Ciocan

Open access · diamondAbstract read
In one paragraph

Article in Romanian journal of morphology and embryology = Revue roumaine de morphologie et embryologie. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 53% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 1 country.

Andreea MoldoveanuDiscipline of Histology and Regenerative Dentistry, Faculty of Dental Medicine, Carol Davila University of Medicine and Pharmacy, Laboratory of Radiobiology, Victor Babeş National Institute of Pathology, Bucharest, Romania; mihnea.nicolescu@umfcd.ro; Department of Prosthesis Technology and Dental Materials, Faculty of Dental Medicine, Carol Davila University of Medicine and Pharmacy, Bucharest, Romania; mirela.bucur@umfcd.ro.
Mihnea Ioan Nicolescu
Mirela Veronica Bucur
George Gabriel Moldoveanu
Cristian Funieru
Ionela Victoria Neagoe
Gina Manda
Tamara Rahela Ioana
Lucian Toma Ciocan
Carol Davila University of Medicine and Pharmacy · ROInstitutul National Victor Babes · ROInstitutul Național de Endocrinologie C.I. Parhon · ROUniversity of Medicine and Pharmacy of Craiova · RO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to assess the in vitro biocompatibility of titanium (Ti) alloy orthodontic mini-implants by correlating human osteoblasts (HOb) response with chemical composition and surface morphology of mini-implants. HOb were cultivated with or without custom-made and commercial mini-implants, discs and filings. The surface morphology and chemical composition of the implants were assessed under the scanning electron microscopy (SEM) with energy-dispersive X-ray (EDX) microanalysis system. Cell viability, adhesion and proliferation were analyzed by optical microscopy and flow cytometry. 3-(4,5-Dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium (MTS) reduction and lactate dehydrogenase (LDH) release tests were used to assess the cytotoxicity of discs and filings-treated culture medium. Shape, adhesion, and multiplication of HOb were not significantly altered by the presence of mini-implants, discs or filings in culture, even though Ti alloy may exert in vitro a low cytotoxic effect on HOb adhered to discs. Morphology analysis by SEM demonstrated that custom-made mini-implants' surface differs from that of commercial mini-screws in terms of surface finish and roughness, whilst EDX analysis showed largely similar percentages of Ti, aluminum and vanadium for the two types of implants. No major differences were noticed regarding the effect exerted in vitro on HOb by the investigated implants. The new mini-implants have a convenient in vitro cytotoxicity profile on HOb.

Indexed as

Dental ImplantsOrthodontic Anchorage ProceduresHumansMicroscopy, Electron, ScanningOsteoblastsSurface PropertiesTitaniumDental ImplantsTitanium

Identifiers

PMID35263407
PMCPMC9019610
OpenAlexW4220975817

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.