ArticleJournal of applied clinical medical physics2022
Method of determining technique from weight and height to achieve targeted detector exposures in portable chest and abdominal digital radiography.
Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 6 citations in OpenAlex.
- Advancing Exposure Index in Radiology for Optimized Imaging, Accuracy, and Future Innovations.Cureus · 2025Review
- Commentary: Achieving ALARA in scoliosis examinations by using body measurements to set techniques and eliminating physical anti-scatter grids.Pediatric radiology · 2024Article
- Performance and reliability assessment of a lower dose, task-based scoliosis radiography protocol in pediatric patients.Pediatric radiology · 2024Article
- Method of determining technique from weight and height to achieve targeted detector exposures in portable chest and abdominal digital radiography.Journal of applied clinical medical physics · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study presents a methodology to develop an X-ray technique chart for portable chest and abdomen imaging which utilizes patient data available in the modality worklist (MWL) to reliably achieve a predetermined exposure index (EI) at the detector for any patient size. The method assumes a correlation between the patients' tissue equivalent thickness and the square root of the ratio of the patient's weight to height. To assess variability in detector exposures, the EI statistics for 75 chest examinations and 99 abdominal portable X-ray images acquired with the new technique chart were compared to those from a single portable unit (chest: 3877 images; abdomen: 200 images) using a conventional technique chart with three patient sizes, and to a stationary radiography room utilizing automatic exposure control (AEC) (chest: 360 images; abdomen: 112 images). The results showed that when using the new technique chart on a group of portable units, the variability in EI was significantly reduced (p < 0.01) for both AP chest and AP abdomen images compared to the single portable using a standard technique chart with three patient sizes. The variability in EI for the images acquired with the new chart was comparable to the stationary X-ray room with an AEC system (p > 0.05). This method could be used to streamline the entire imaging chain by automatically selecting an X-ray technique based on patient demographic information contained in the MWL to provide higher quality examinations to clinicians by eliminating outliers. In addition, patient height and weight can be used to estimate the patients' tissue equivalent thickness.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.