Evidence map›Paper›PMID 35256627›Full record

ArticleScientific reports2022

Continuous cardiac thermometry via simultaneous catheter tracking and undersampled radial golden angle acquisition for radiofrequency ablation monitoring.

Maxime Yon, Marylène Delcey, Pierre Bour, William Grissom, Bruno Quesson, Valéry Ozenne

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 5 institutions in 2 countries.

Maxime YonIHU Liryc, Electrophysiology and Heart Modeling Institute, Hopital Xavier Arnozan, Foundation Bordeaux Université, Avenue du Haut Lévêque, 33604, Pessac Cedex, France. maxime.yon@gmail.com.
Marylène DelceyIHU Liryc, Electrophysiology and Heart Modeling Institute, Hopital Xavier Arnozan, Foundation Bordeaux Université, Avenue du Haut Lévêque, 33604, Pessac Cedex, France.
Pierre BourIHU Liryc, Electrophysiology and Heart Modeling Institute, Hopital Xavier Arnozan, Foundation Bordeaux Université, Avenue du Haut Lévêque, 33604, Pessac Cedex, France.
William GrissomDepartment of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN, 37235, USA.
Bruno QuessonIHU Liryc, Electrophysiology and Heart Modeling Institute, Hopital Xavier Arnozan, Foundation Bordeaux Université, Avenue du Haut Lévêque, 33604, Pessac Cedex, France.
Valéry OzenneIHU Liryc, Electrophysiology and Heart Modeling Institute, Hopital Xavier Arnozan, Foundation Bordeaux Université, Avenue du Haut Lévêque, 33604, Pessac Cedex, France.
Centre de Recherche Cardio-Thoracique de Bordeaux · FRElectrophysiology and Heart Modeling Institute · FRHôpital Xavier Arnozan · FRInserm · FRVanderbilt University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The complexity of the MRI protocol is one of the factors limiting the clinical adoption of MR temperature mapping for real-time monitoring of cardiac ablation procedures and a push-button solution would ease its use. Continuous gradient echo golden angle radial acquisition combined with intra-scan motion correction and undersampled temperature determination could be a robust and more user-friendly alternative than the ultrafast GRE-EPI sequence which suffers from sensitivity to magnetic field susceptibility artifacts and requires ECG-gating. The goal of this proof-of-concept work is to establish the temperature uncertainty as well as the spatial and temporal resolutions achievable in an Agar-gel phantom and in vivo using this method. GRE radial golden angle acquisitions were used to monitor RF ablations in a phantom and in vivo in two sheep hearts with different slice orientations. In each case, 2D rigid motion correction based on catheter micro-coil signal, tracking its motion, was performed and its impact on the temperature imaging was assessed. The temperature uncertainty was determined for three spatial resolutions (1 × 1 × 3 mm

Indexed as

Catheter AblationThermometryAnimalsCathetersHeartMagnetic Resonance ImagingPhantoms, ImagingSheep

Identifiers

PMID35256627
PMCPMC8901729
OpenAlexW4220888631

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.