ArticleBMC musculoskeletal disorders2022
Three-dimensional reconstruction and virtual reposition of fragments compared to two dimensional measurements of midshaft clavicle fracture shortening.
Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Limitations in rotational correction: 3D displacement analysis of midshaft clavicle fractures with titanium elastic nails.Scientific reports · 2025Article
- SHORTENING OF CLAVICLE FRACTURES: PHYSICALActa ortopedica brasileira · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMidshaft clavicle fracture shortening measurement is a reported key element for indication to surgical management and reporting of clinical trials. Determination of pre-fracture clavicle length for shortening measurement remains an unresolved issue. The purpose of the study was to assess accuracy of a novel technique of three-dimensional reconstruction and virtual reposition of bone fragments (3D-VR) for determination of pre-fracture clavicle length and measurement of shortening.
methodsAccuracy of 3D-VR measurements was assessed using 5 synthetic bone clavicle fracture models. Measurements were compared between caliper and 3D-VR technique measurements. Correlation between 3D-VR and 2D measurements on standard radiographs was assessed on a cohort of 20 midshaft fractures. Four different methods for 2D measurements were assessed.
resultsMean difference between caliper measurements and 3D-VR was 0.74 mm (95CI = - 2.51;3.98) (p = 0.56) on synthetic fracture models. Mean differences between 3D-VR and standard radiograph shortening measurement methods were 11.95 mm (95CI = 7.44;16.46) for method 1 (Jeray et al.) and 9.28 mm (95CI = 4.77;13.79) for method 2 (Smekal et al.) (p < 0.05). Differences were - 1.02 mm (95CI = - 5.53;3.48) for method 3 (Silva et al.) and - 2.04 mm (95CI = - 6.55;2.47) for method 4 (own method). Interobserver correlation ranged between 0.85 and 0.99. A false positive threshold of 20 mm was measured by the two observers in 25% of the case according to method of method 1, 30-35% with method 2, 15% with method 3 et al. and 5-10% with the method 4.
conclusion3D VR is accurate in measuring midshaft clavicle fracture length and shortening. Two dimensional measurements may be used for approximation of clavicular shortening.