Evidence map›Paper›PMID 35251571›Full record

ArticleJournal of healthcare engineering2022

Clinical Care of Hyperthyroidism Using Wearable Medical Devices in a Medical IoT Scenario.

Lili Wei, Sujuan Hou, Qiuxia Liu

RetractedOpen access · hybridAbstract readRetracted Publication
In one paragraph

Article in Journal of healthcare engineering, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It has been retracted, and should not be counted. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Lili WeiDepartment of Radiology, Tangshan Gongren Hospital, Tangshan, Hebei 063000, China.
Sujuan HouDepartment of Radiology, Tangshan Gongren Hospital, Tangshan, Hebei 063000, China.ORCID 0000-0001-9799-3624
Qiuxia LiuDepartment of Radiology, Tangshan Gongren Hospital, Tangshan, Hebei 063000, China.
Tangshan Gongren Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents an in-depth study and analysis of clinical care of patients with hyperthyroidism using wearable medical devices in the context of medical IoT scenarios. According to the use scenario of the gateway and the connectivity of the equipment, the hardware architecture, hardware interfaces, functionality, and performance of the gateway were briefly designed, so as to monitor patients with hyperthyroidism more comprehensively and save labor costs. The gateway can provide access to different devices and adaptation functions to different hardware interfaces and provide hardware support for the subsequent deployment of the proposed new medical communication protocols and related information systems. A medical data convergence information system based on multidevice management and multiprotocol parsing was designed and implemented. The system enables the management and configuration of different medical devices and access to data through the targeted parsing of the underlying medical device communication protocols. The system also provides the automatic adaptation of multiple types of underlying medical device communication protocols and automatic parsing of multiple versions and can provide multiple devices to process fused data streams or device information and data from a single device. The use of event-driven asynchronous communication eliminates the tight dependency on service invocation in the synchronous communication approach. The use of a metadata-based data model structure enables model extensions to accommodate the impact of iterative business requirements on the database structure. Real-time patient physiological data transmission for intraoperative monitoring based on the MQTT protocol and video transmission for intraoperative patient monitoring based on the RTMP protocol were implemented. The development of the intelligent medical monitoring service system was completed, and the system was tested, optimized, and deployed. The functionality and performance of the system were tested, the performance issue of slow query speed was optimized, and the deployment of the project using Docker containers was automated.

Indexed as

HyperthyroidismWearable Electronic DevicesHumansMonitoring, Physiologic

Identifiers

PMID35251571
PMCPMC8890839
OpenAlexW4212794825

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.