ArticleClinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis
Evaluation of DOAC Dipstick Test for Detecting Direct Oral Anticoagulants in Urine Compared with a Clinically Relevant Plasma Threshold Concentration.
Article in Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 1 synthesis or guideline pooled it, 9 citations in OpenAlex.
- Rapid assessment of direct oral anticoagulants in acute stroke-An educational systematic review.European stroke journal · 2025Pooled it
- Diagnostic Performance of a DOAC Urine Dipstick in Obese Outpatients with Atrial Fibrillation: Comparison with Plasma Concentrations.Journal of clinical medicine · 2026Article
- Feasibility of Direct Oral Anticoagulant Dipstick Point-of-Care Testing in Patients with Acute Stroke and Transient Ischaemic Attack.Cerebrovascular diseases extra · 2026Article
- The methods for removal of direct oral anticoagulants and heparins to improve the monitoring of hemostasis: a narrative literature review.Thrombosis journal · 2023Review
- Can We Improve on the Rapid Assessment of Clinically Relevant Levels of Direct Acting Oral Anticoagulants (DOAC)?Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/HemostasisArticle
- Comparison of the DOAC Dipstick Test on Urine Samples With Chromogenic Substrate Methods on Plasma Samples in Outpatients Treated With Direct Oral Anticoagulants.Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/HemostasisObservational
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Measuring direct oral anticoagulant (DOAC) concentrations might be necessary in certain clinical situations but is not routinely performed. The DOAC Dipstick is a new rapid test for detecting DOACs in urine. The aim of this study was to evaluate the possible uses and limitations of the DOAC Dipstick and to compare visual analysis and DOASENSE Reader analysis of DOAC Dipstick pads. Plasma and urine samples were collected from 23 patients taking DOACs. DOAC concentrations in plasma and urine were measured by chromogenic substrate assays and in urine also by the DOAC Dipstick. Plasma concentrations were dichotomized at a threshold of ≥30 ng/mL. Patient samples were compared with samples from control individuals not using anticoagulants (n = 10) and with DOASENSE control urines. The Combur-10 test was used to measure parameters that may affect urine color and hence the interpretation of the DOAC Dipstick result. DOAC Dipstick test results were positive in 21/23 patient urine samples at a plasma DOAC concentration of ≥30 ng/mL and in 2/23 patient urine samples at a plasma DOAC concentration of <30 ng/mL. Inter-observer agreement was above 90% for visual analysis of patient urine samples and was 100% for DOASENSE Reader analysis of patient urines and for analysis of control group urines and DOASENSE control urines. Abnormalities in urine color detected by the Combur-10 test did not affect the DOAC Dipstick results. DOAC Dipstick detects DOACs in urine at a plasma threshold of ≥30 ng/mL. Positive DOAC Dipstick results should be confirmed by measuring DOAC plasma concentration.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.