ArticleHeart rhythm O22022
Prospective long-term follow-up of silicone-polyurethane-insulated implantable cardioverter-defibrillator leads.
Article in Heart rhythm O2, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Why and When ICD Leads Are Extracted: Does the ICD Lead Model Influence Lead Survival?Medicina (Kaunas, Lithuania) · 2025Article
- In Vivo Durability of Polyurethane Insulated Implantable Cardioverter Defibrillator (ICD) Leads.Polymers · 2024Article
- Externalized conductors and electrical dysfunction in transvenous ventricular leads: Results of the Cardiac Lead Assessment Study.Heart rhythm O2 · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundSt Jude Medical (now Abbott) Optim-insulated implantable cardioverter-defibrillator (ICD) leads were expected to overcome problems with insulation abrasion and externalized conductors in earlier models. Long-term follow-up is essential to the evaluation of lead performance.
objectiveTo determine, in a prospective cohort of Optim-insulated ICD leads, the rates of all-cause mechanical failure and its subtypes (conductor fracture, insulation abrasion, externalized conductors, and other mechanical failures) and electrical dysfunction adjudicated as nonmechanical failure.
methodsAbbott established 3 prospective registries, enrolling 11,155 leads among 10,872 patients beginning in 2006. There was standardized baseline documentation, 6-monthly follow-up, adverse events reporting, and documentation of lead revision or inactivation, study withdrawal, and death or transplant. The Population Health Institute (McMaster University) reviewed database functions, adjudicated all potential mechanical lead failures, and conducted independent data analyses.
resultsDuring a median follow-up of 4.6 years, there were 171 mechanical failures (1.53%, 95.4% freedom from failure by 12 years). There were no significant differences in survival among Durata DF4 and DF1 and Riata ST Optim leads. The year-to-year rate of failure of leads increased over time. There were 69 electrical dysfunctions (0.62%, 98.8% freedom from failure by 12 years) adjudicated as nonmechanical failure.
conclusionDuring follow-up as long as 12 years (median 4.6 years), Optim-insulated leads had low rates of mechanical failure and electrical dysfunction. Independent analyses provide reliable data on the long-term outcomes essential to analyzing ICD lead performance.