Evidence map›Paper›PMID 35241879›Full record

ArticleJournal of orthopaedics

The use of mobile bearing TKA in valgus deformities - A clinical study.

Gianluca Castellarin, Edoardo Bori, Mathieu Biava, Giacomo Talevi, Bernardo Innocenti

Open access · bronzeAbstract read
In one paragraph

Article in Journal of orthopaedics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 71% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Gianluca CastellarinSuzzara Hospital, Mantua, Italy.
Edoardo BoriBEAMS Department, Université Libre de Bruxelles, Bruxelles, Belgium.
Mathieu BiavaBEAMS Department, Université Libre de Bruxelles, Bruxelles, Belgium.
Giacomo TaleviBEAMS Department, Université Libre de Bruxelles, Bruxelles, Belgium.
Bernardo InnocentiBEAMS Department, Université Libre de Bruxelles, Bruxelles, Belgium.
Université Libre de Bruxelles · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe number of patients presenting valgus deformities undergoing total knee arthroplasty (TKA) represents approximately 10% of the total number of TKAs performed: the presence of valgus deformity requires the implant to have proper alignment, stability and balance to achieve successful clinical outcomes, especially for knees with high coronal deformities, but these have proven to be difficult goals to achieve and therefore the use of constrained prostheses is often recommended for these cases. However, even though the use of unconstrained mobile bearing for severe knee deformities is rare, it has been shown to give successful outcomes and therefore the aim of this study is to evaluate whether this surgical technique can achieve satisfactory clinical results and correct alignment, as well as good patient satisfaction.

methodsThis study presents the results of 69 TKA performed with cemented mobile bearing implants by a single surgeon on knee affected by valgus deformities. Asymmetric inserts were adopted for all the implants and an alignment surgical tool, dedicated for valgus patients, was used during the operation. Angles of valgus, WOMAC surveys and Numeric Rating Scale for pain were recorded to evaluate the results of the operations.

resultsA total of 67 pre-op WOMAC questionnaire surveys were collected, with the mean result of this evaluation being 15.9 points. The Numeric Rating Scale for pain had an average of 2.2 for 68 tests. The deformities were corrected from a mean total preoperative valgus angle of 12.5° to a postoperative valgus deformity average of 0.6°. During follow-up, only one patient had serious complications due to the rupture of the extensor apparatus following a domestic accident involving falling. Further 10 patients have mild complications related to injuries such as pain of varying intensity, burning, or swelling of the knee. The level of satisfaction from 0 to 10 (0 not at all satisfied and 10 perfectly satisfied) had an average score of 7.7.

conclusionsThe surgical approach presented, involving a less constrained model if compared to the ones usually chosen, allowed to achieve correct alignment and high patient satisfaction using mobile bearing implants on valgus knee deformities; further patient follow-up will be performed to evaluate long-term outcomes, but the results achieved already represent a significative finding.

Indexed as

CementedMobile bearingNovel surgical techniqueTotal knee arthroplastyValgus deformity

Identifiers

PMID35241879
PMCPMC8858731
OpenAlexW4200289362

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.