Evidence map›Paper›PMID 35239851›Full record

ArticleRevista do Colegio Brasileiro de Cirurgioes2022

Robotic re-TAPP: a minimally invasive alternative for the failed posterior repair.

Pedro Henrique DE Freitas Amaral, Luca Giovanni Antonio Pivetta, Eduardo Rullo Maranhão Dias, João Paulo Venancio DE Carvalho, Marcelo Furtado, Carlos Alberto Malheiros, Sergio Roll

Open access · goldAbstract read
In one paragraph

Article in Revista do Colegio Brasileiro de Cirurgioes, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Pedro Henrique DE Freitas Amaral- Hospital Alemão Oswaldo Cruz, Centro de Hérnia - São Paulo - SP - Brasil.ORCID http://orcid.org/0000-0003-3999-210X
Luca Giovanni Antonio Pivetta- Hospital Alemão Oswaldo Cruz, Centro de Hérnia - São Paulo - SP - Brasil.
Eduardo Rullo Maranhão Dias- Hospital Alemão Oswaldo Cruz, Centro de Hérnia - São Paulo - SP - Brasil.
João Paulo Venancio DE Carvalho- Hospital Alemão Oswaldo Cruz, Centro de Hérnia - São Paulo - SP - Brasil.
Marcelo Furtado- Hospital Alemão Oswaldo Cruz, Centro de Hérnia - São Paulo - SP - Brasil.
Carlos Alberto Malheiros- Santa Casa de São Paulo, Grupo de Parede Abdominal e Cirurgia Bariátrica - Departamento de Cirurgia - São Paulo - SP - Brasil.
Sergio Roll- Hospital Alemão Oswaldo Cruz, Centro de Hérnia - São Paulo - SP - Brasil.
Hospital Alemão Oswaldo Cruz · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveto describe the use of the robotic platform in inguinal hernia recurrence after a previous laparoscopic repair.

methodspatients with recurrent inguinal hernias following a laparoscopic repair who have undergone robotic transabdominal preperitoneal between December 2015 through September 2020 were identified in a prospectively maintained database. Outcomes of interest included demographics, hernia characteristics, operative details and rates of 30-day surgical site occurrence, surgical site occurrences requiring procedural interventions, surgical site infection and hernia recurrence were abstracted.

resultsnineteen patients (95% male, mean age 55 years, mean body mass index 28) had 27 hernias repaired (N=8 bilateral). Average operative time was 168.9 ± 49.3min (range 90-240). There were two intraoperative complications all of them were bleeding from the inferior epigastric vessel injuries. Three SSOs occurred (N=2 seromas and N=1 hematoma. After a median 35.7 months follow-up (IQR 13-49), no recurrence has been diagnosed. One patient developed chronic postoperative inguinal pain.

conclusionson a small number of selected patients and experienced hands, we found that the use of the robotic platform for repair of recurrent hernias after prior laparoscopic repair appears to be feasible, safe and effective despite being technically demanding. Further studies in larger cohorts are necessary to determine if this technique provides any benefits in recurrent inguinal hernia scenario.

Indexed as

Hernia, InguinalLaparoscopyRobotic Surgical ProceduresFemaleGroinHerniorrhaphyHumansMaleMiddle AgedRecurrenceRetrospective StudiesSurgical MeshTreatment Outcome

Identifiers

PMID35239851
PMCPMC10578846
OpenAlexW4214874621

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.