Evidence map›Paper›PMID 35237925›Full record

ArticleMedical & biological engineering & computing2022

The evaluation of artificial talus implant on ankle joint contact characteristics: a finite element study based on four subjects.

Tao Liu, Nadr Jomha, Samer Adeeb, Marwan El-Rich, Lindsey Westover

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.8field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Design of a lightweight universal talus implant using topology optimization.Frontiers in bioengineering and biotechnology · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Tao LiuFaculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada. tao6@ualberta.ca.ORCID http://orcid.org/0000-0003-3171-4105
Nadr JomhaFaculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada.
Samer AdeebFaculty of Civil and Environmental Engineering, University of Alberta, Edmonton, Alberta, Canada.
Marwan El-RichDepartment of Mechanical Engineering, Khalifa University, Abu Dhabi, United Arab Emirates.
Lindsey WestoverDepartment of Mechanical Engineering, University of Alberta, Edmonton, Alberta, Canada.
University of Alberta · CAKhalifa University of Science and Technology · AE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Customized talus implants have been regarded as a better treatment alternative to talus avascular necrosis than traditional surgical fusion because of its ability to maintain joint mobility while ameliorating pain. Despite the use of ankle hemiarthroplasty clinically, the cartilage contact characteristics of adjacent bones remain unclear. This study aims to use finite element modeling to evaluate the contact characteristics of three types of cobalt-chrome talus implants in three postures, in four subjects. This study also compared the contact area, contact pressure, and peak contact pressure of the implant models with a reference biological model. Among the various biological and implant models, our results showed that the biological models generally had the largest contact areas and smallest peak contact pressures, whereas the implant-type models had smaller contact areas and relatively larger peak contact pressure. Moreover, among the three implant types, customized-scale models showed a larger total contact area than that of the SSM-scale and universal-scale models, but their variation was relatively limited. The results from this study can have significance in future endeavors into ankle joint modeling, as well as being able to improve implant design to enhance recovery outcomes for patients who may benefit from talar replacement.

Indexed as

Ankle JointTalusAnkleFinite Element AnalysisHumansRange of Motion, ArticularContact characteristics of cartilageFinite element modelTotal talus replacementUniversal talus implant design