ArticleArthroplasty (London, England)2021

Quantification of assembly forces during creation of head-neck taper junction considering soft tissue bearing: a biomechanical study.

Toni Wendler, Torsten Prietzel, Robert Möbius, Jean-Pierre Fischer, Andreas Roth, Dirk Zajonz

Abstract read
In one paragraph

Article in Arthroplasty (London, England), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Importance of surgical assembly technique on the engagement of 12/14 modular tapers.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Toni WendlerZESBO - Centre for Research on Musculoskeletal Systems, Leipzig University, Semmelweisstraße 14, 04103, Leipzig, Germany. toni.wendler@zesbo.de.
Torsten PrietzelDepartment of Orthopaedics, Trauma and Reconstructive Surgery, Zeisigwaldkliniken Bethanien, Chemnitz, Germany.
Robert MöbiusZESBO - Centre for Research on Musculoskeletal Systems, Leipzig University, Semmelweisstraße 14, 04103, Leipzig, Germany.
Jean-Pierre FischerZESBO - Centre for Research on Musculoskeletal Systems, Leipzig University, Semmelweisstraße 14, 04103, Leipzig, Germany.
Andreas RothDepartment of Orthopaedic, Trauma and Plastic Surgery, Leipzig University, Leipzig, Germany.
Dirk ZajonzZESBO - Centre for Research on Musculoskeletal Systems, Leipzig University, Semmelweisstraße 14, 04103, Leipzig, Germany.

Funding

Central Innovation Programme for SMEs 944000-033
6 · The paper itself

Abstract

backgroundAll current total hip arthroplasty (THA) systems are modular in design. Only during the operation femoral head and stem get connected by a Morse taper junction. The junction is realized by hammer blows from the surgeon. Decisive for the junction strength is the maximum force acting once in the direction of the neck axis, which is mainly influenced by the applied impulse and surrounding soft tissues. This leads to large differences in assembly forces between the surgeries. This study aimed to quantify the assembly forces of different surgeons under influence of surrounding soft tissue.

methodsFirst, a measuring system, consisting of a prosthesis and a hammer, was developed. Both components are equipped with a piezoelectric force sensor. Initially, in situ experiments on human cadavers were carried out using this system in order to determine the actual assembly forces and to characterize the influence of human soft tissues. Afterwards, an in vitro model in the form of an artificial femur (Sawbones Europe AB, Malmo, Sweden) with implanted measuring stem embedded in gelatine was developed. The gelatine mixture was chosen in such a way that assembly forces applied to the model corresponded to those in situ. A study involving 31 surgeons was carried out on the aforementioned in vitro model, in which the assembly forces were determined.

resultsA model was developed, with the influence of human soft tissues being taken into account. The assembly forces measured on the in vitro model were, on average, 2037.2 N ± 724.9 N, ranging from 822.5 N to 3835.2 N. The comparison among the surgeons showed no significant differences in sex (P = 0.09), work experience (P = 0.71) and number of THAs performed per year (P = 0.69).

conclusionsAll measured assembly forces were below 4 kN, which is recommended in the literature. This could lead to increased corrosion following fretting in the head-neck interface. In addition, there was a very wide range of assembly forces among the surgeons, although other influencing factors such as different implant sizes or materials were not taken into account. To ensure optimal assembly force, the impaction should be standardized, e.g., by using an appropriate surgical instrument.

Indexed as

Assembly forceBiomechanical studyHead‐neck taper junctionSoft tissueTotal hip arthroplasty

Identifiers

PMID35236493
PMCPMC8796494

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked