Evidence map›Paper›PMID 35236465›Full record

ArticleArthroplasty (London, England)2020

Increasing efficiency by optimizing table position for elective primary THA and TKA: a prospective monocentric pilot study.

Dirk Zajonz, Celina Höhn, Juliane Neumann, Christine Angrick, Robert Möbius, Gerald Huschak, Thomas Neumuth, Mohamed Ghanem, Andreas Roth

Open access · diamondAbstract read
In one paragraph

Article in Arthroplasty (London, England), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Dirk Zajonz *Department of Orthopaedic Surgery, Traumatology and Plastic Surgery, University Hospital Leipzig, Liebigstrasse 20, D-04103, Leipzig, Germany. dirk.zajonz@ediacon.de.
Celina Höhn *Department of Orthopaedic Surgery, Traumatology and Plastic Surgery, University Hospital Leipzig, Liebigstrasse 20, D-04103, Leipzig, Germany.
Juliane NeumannInnovation Center Computer Assisted Surgery (ICCAS), Leipzig University, Semmelweisstraße 14, D-04103, Leipzig, Germany.
Christine AngrickInnovation Center Computer Assisted Surgery (ICCAS), Leipzig University, Semmelweisstraße 14, D-04103, Leipzig, Germany.
Robert MöbiusZESBO - Center for Research on Musculoskeletal Systems, University of Leipzig, Semmelweisstrasse 14, D-04103, Leipzig, Germany.
Gerald HuschakClinic for Anesthesiology and Intensive Therapy, University Hospital Leipzig, Liebigstrasse 20, D-04103, Leipzig, Germany.
Thomas NeumuthInnovation Center Computer Assisted Surgery (ICCAS), Leipzig University, Semmelweisstraße 14, D-04103, Leipzig, Germany.
Mohamed Ghanem *Department of Orthopaedic Surgery, Traumatology and Plastic Surgery, University Hospital Leipzig, Liebigstrasse 20, D-04103, Leipzig, Germany.
Andreas Roth *Department of Orthopaedic Surgery, Traumatology and Plastic Surgery, University Hospital Leipzig, Liebigstrasse 20, D-04103, Leipzig, Germany.
University Hospital Leipzig · DELeipzig University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionHip and knee arthroplasties are very frequently performed surgeries with high quality standards and continuous optimization potential. Intraoperative processes can be standardized and simplified by optimization of table setups in the operating room to improve the quality and to increase efficiency. PATIENTS AND

methodsThe existing surgical setups for primary hip and knee arthroplasties in a university maximum care hospital with endoprosthesis center were simulated and analysed with a computer program and optimized setup suggestions were worked out, based on handover times, walking distance and ergonomic aspects determined in the program. In a prospective monocentric analysis, primary hip arthroplasties and knee arthroplasties were examined in currently used and in the new optimized setups (standard procedure according to in-house SOP, senior and main surgeons, no assistants). The surgeries were externally and independently supervised and analysed, whereby the time between incision and suture beginning, handovers per minute and handover times were documented, amongst other things. In addition, an evaluation sheet, which showed the satisfaction with the new setup, was filled by the surgical team.

resultsIn the period from April 2016 to December 2018, 19 hip arthroplasties in currently used and 15 in the new optimized setup as well as 9 knee arthroplasties in currently used and 13 in the new setup were performed. Attention was paid to constant conditions in the compared groups and disruptive factors (assisted surgeries, complex surgeries, different cementings, etc.) were excluded. In the group of hip arthroplasties, the handover times were significantly different (old 1.82 +/- 1.43 s.; new 1.08 +/- 0.78 s.; p <0.001), as well as the handovers per minute (old 1.62 +/- 0.45 handovers/min.; new 2.10 +/- 0.32 handovers/min.; p = 0,001). The time between incision and suture beginning indicated no significant difference (old 53.89 +/- 18.92 min.; new 49.73 +/- 12.18 min; p = 0.466): During the knee arthroplasties, handovers per minute were significantly different (old 1.83 +/- 0.38 handovers/min.; new 2.40 +/- 0.35 handovers/min.; p = 0.002). The time between incision and suture beginning (old 71.11 +/- 20.72 min.; new 70.69 +/- 17.12 min.; p = 0.959) and the handover times (old 1.06 +/- 0.64 s.; new 0.91 +/- 0.59 s.; p = 0.152) indicated no significant difference. The evaluation of the questionnaires showed a significant difference (p < 0.001) in the group of hip arthroplasties in the category "visibility". For the knee arthroplasties, all items except "visibility" (p = 0.261) differed significantly. Overall, a high level of staff satisfaction with the new setup was achieved.

conclusionsIn both groups, more handovers per minute could be achieved in the optimized setup and in the group of the hip arthroplasties, the handover times were significantly faster. The evaluation sheet showed a high satisfaction of the surgical staff with the new setup. No reduction of the time between incision and suture beginning could be determined. This can be attributed to a certain training effect, the adjustment to the setup modification and the low number of cases. The new setup offers a practical alternative for hip arthroplasties as well as for knee arthroplasties as it optimizes the events in the operating room in many ways. For example, there were more handovers per minute possible and passing of the surgical instruments free from interferences. Moreover, it increases the efficiency and achieves a high satisfaction of the staff.

Indexed as

Increase of efficiencyOperating roomTable positionTHATKA

Identifiers

PMID35236465
PMCPMC8796529
OpenAlexW3093850054

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked