Evidence map›Paper›PMID 35236457›Full record

ArticleArthroplasty (London, England)2020

Trunnion fracture of femoral prosthesis following a large metal-on-metal uncemented total hip arthroplasty: a case report.

Krishna Kiran Eachempati, Chandra Sekhar Dannana, Sunil Apsingi, Vinay Kishore Ponnala, Giridhar Boyapati, Apurve Parameswaran

Open access · diamondAbstract read
In one paragraph

Article in Arthroplasty (London, England), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.6field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Krishna Kiran EachempatiDepartment of Orthopaedics, Medicover (formerly MaxCure) Hospital, Opposite Cyber Gateway, Ibis Hotel lane, Hi-Tech City, Hyderabad, Madhapur, Telangana State, 500081, India.ORCID https://orcid.org/0000-0003-1416-9918
Chandra Sekhar DannanaDepartment of Orthopaedics, Medicover (formerly MaxCure) Hospital, Opposite Cyber Gateway, Ibis Hotel lane, Hi-Tech City, Hyderabad, Madhapur, Telangana State, 500081, India.
Sunil ApsingiDepartment of Orthopaedics, Medicover (formerly MaxCure) Hospital, Opposite Cyber Gateway, Ibis Hotel lane, Hi-Tech City, Hyderabad, Madhapur, Telangana State, 500081, India.
Vinay Kishore PonnalaDepartment of Orthopaedics, Medicover (formerly MaxCure) Hospital, Opposite Cyber Gateway, Ibis Hotel lane, Hi-Tech City, Hyderabad, Madhapur, Telangana State, 500081, India.
Giridhar BoyapatiDepartment of Orthopaedics, Medicover (formerly MaxCure) Hospital, Opposite Cyber Gateway, Ibis Hotel lane, Hi-Tech City, Hyderabad, Madhapur, Telangana State, 500081, India.
Apurve ParameswaranDepartment of Orthopaedics, Medicover (formerly MaxCure) Hospital, Opposite Cyber Gateway, Ibis Hotel lane, Hi-Tech City, Hyderabad, Madhapur, Telangana State, 500081, India. doctorapurve@gmail.com.ORCID https://orcid.org/0000-0003-2070-2256
MaxCure Hospitals · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTrunnion fracture of the femoral prosthesis is an extremely rare complication following Total Hip Arthroplasty (THA). There are very few reports in literature on trunnion fracture. All previously reported cases are of prostheses with smaller heads, unlike the large metal-on-metal articulation in our case, which is unique. CASE PRESENTATION: A 29-year-old male patient with juvenile idiopathic arthropathy presented to us with a fracture of the trunnion of his left THA, with no history of trauma. He had undergone staged bilateral THA for avascular necrosis of the hips 10 years ago (with AML-A stem and large metal-on-metal articulation bilaterally). We revised the THA and exchanged both femoral and acetabular components. He had a good functional outcome at 3 years' follow up.

conclusionThe primary reason for the trunnion fracture in our case was the faulty stem design of the AML [with a small (9/10) taper, and a large head], causing excessive bending moment at the trunnion, worsening the cantilever effect and leading to subsequent cyclic fatigue failure. Whilst gross trunnion failure (GTF) with dissociation of the head from the taper is commonly reported, trunnion fracture per se is a rare and devastating complication. The AML-A stem has since been recalled by the company and there is a need to constantly monitor these patients for potential trunnion-related complications.

Indexed as

Metal on metalRevision hip arthroplastyTrunnion fractureTrunnionosisUncemented hip arthroplasty

Identifiers

PMID35236457
PMCPMC8796406
OpenAlexW3094712985

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.