Evidence map›Paper›PMID 35236432›Full record

ArticleArthroplasty (London, England)2020

MRI-based or CT-based patient-specific instrumentation in Total knee Arthroplasty: How do the two systems compare?

Dong-Geun Kang, Kang-Il Kim, Jung-Kwon Bae

Abstract read
In one paragraph

Article in Arthroplasty (London, England), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Dong-Geun KangDepartment of Orthopaedic Surgery, Kyung Hee University Hospital at Gangdong, 892 Dongnam-ro, Gangdong-gu, Seoul, 134-727, South Korea.
Kang-Il KimDepartment of Orthopaedic Surgery, Kyung Hee University Hospital at Gangdong, 892 Dongnam-ro, Gangdong-gu, Seoul, 134-727, South Korea. khuknee@gmail.com.ORCID http://orcid.org/0000-0002-4010-1063
Jung-Kwon BaeDepartment of Orthopaedic Surgery, Kyung Hee University Hospital at Gangdong, 892 Dongnam-ro, Gangdong-gu, Seoul, 134-727, South Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPatient-specific instrumentation (PSI) has been introduced into total knee arthroplasty (TKA) to improve accuracy in restoration of alignment. PSI in TKA refers to custom-made cutting jigs manufactured according to anatomic configuration of the patient's bone based on preoperative magnetic resonance imaging (MRI) or computed tomography (CT) scans. The purpose of this study was to compare the MRI- or CT-based PSI to see if they could reproduce accurate bone resection and postoperative outcomes.

methodsSeventy-one patients who received elective TKA using a PSI system for primary osteoarthritis with varus deformity were prospectively enrolled for this study. We randomly allocated those patients to MRI-based PSI group (36 patients) and CT-based PSI group (35 patients). The actual resection thickness and planned resection thickness by preoperative PSI electronic program were compared between the two groups. Radiographic findings of the postoperative limb alignment, three-dimensional position of the implants, and related complications were also evaluated. Clinical evaluation was also performed before and 2 years after the surgery.

resultsThere were no significant differences in the resection thickness in femur and tibia between actual resection and planned resection in both groups. Furthermore, there were no significant differences between two groups in terms of coronal, sagittal and rotational alignment of the components. All clinical assessments revealed no differences between two groups 2 years after the operation. No specific complication related to PSI was observed.

conclusionsAlthough MRI allows for visualization of cartilage, MRI-based PSI system did not show better accuracy in predicting the thickness of bone resection than CT-based PSI. Moreover, there were no differences in radiographic and clinical outcomes between the two groups.

Indexed as

Computed tomographyMagnetic resonance imagePatient specific instrumentationTotal knee arthroplasty

Identifiers

PMID35236432
PMCPMC8796460

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked