ArticleJMIR formative research2022

Heart Rate Measurement Accuracy of Fitbit Charge 4 and Samsung Galaxy Watch Active2: Device Evaluation Study.

Michael Nissen, Syrine Slim, Katharina Jäger, Madeleine Flaucher, Hanna Huebner, Nina Danzberger, Peter A Fasching, Matthias W Beckmann, Stefan Gradl, Bjoern M Eskofier

Abstract read
In one paragraph

Article in JMIR formative research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 33 papers.

0numbers the graph read from it
0cells of the map it votes in
33citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

33 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. From Stagnation to Strategy: Challenges in Advancing Long COVID Research.Journal of evaluation in clinical practice · 2025
    Review
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Article
  20. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Michael NissenDepartment Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany.ORCID https://orcid.org/0000-0001-5472-132X
Syrine SlimDepartment Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany.ORCID https://orcid.org/0000-0003-1283-5403
Katharina JägerDepartment Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany.ORCID https://orcid.org/0000-0002-2478-4079
Madeleine FlaucherDepartment Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany.ORCID https://orcid.org/0000-0002-8086-1112
Hanna HuebnerDepartment of Gynecology and Obstetrics, Erlangen University Hospital, Erlangen, Germany.ORCID https://orcid.org/0000-0001-6889-1493
Nina DanzbergerDepartment of Gynecology and Obstetrics, Erlangen University Hospital, Erlangen, Germany.ORCID https://orcid.org/0000-0003-0255-3760
Peter A FaschingDepartment of Gynecology and Obstetrics, Erlangen University Hospital, Erlangen, Germany.ORCID https://orcid.org/0000-0003-4885-8471
Matthias W BeckmannDepartment of Gynecology and Obstetrics, Erlangen University Hospital, Erlangen, Germany.ORCID https://orcid.org/0000-0002-8441-693X
Stefan GradlDepartment Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany.ORCID https://orcid.org/0000-0003-1443-7652
Bjoern M EskofierDepartment Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany.ORCID https://orcid.org/0000-0002-0417-0336

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFitness trackers and smart watches are frequently used to collect data in longitudinal medical studies. They allow continuous recording in real-life settings, potentially revealing previously uncaptured variabilities of biophysiological parameters and diseases. Adequate device accuracy is a prerequisite for meaningful research.

objectiveThis study aims to assess the heart rate recording accuracy in two previously unvalidated devices: Fitbit Charge 4 and Samsung Galaxy Watch Active2.

methodsParticipants performed a study protocol comprising 5 resting and sedentary, 2 low-intensity, and 3 high-intensity exercise phases, lasting an average of 19 minutes 27 seconds. Participants wore two wearables simultaneously during all activities: Fitbit Charge 4 and Samsung Galaxy Watch Active2. Reference heart rate data were recorded using a medically certified Holter electrocardiogram. The data of the reference and evaluated devices were synchronized and compared at 1-second intervals. The mean, mean absolute error, mean absolute percentage error, Lin concordance correlation coefficient, Pearson correlation coefficient, and Bland-Altman plots were analyzed.

resultsA total of 23 healthy adults (mean age 24.2, SD 4.6 years) participated in our study. Overall, and across all activities, the Fitbit Charge 4 slightly underestimated the heart rate, whereas the Samsung Galaxy Watch Active2 overestimated it (-1.66 beats per minute [bpm]/3.84 bpm). The Fitbit Charge 4 achieved a lower mean absolute error during resting and sedentary activities (seated rest: 7.8 vs 9.4; typing: 8.1 vs 11.6; laying down [left]: 7.2 vs 9.4; laying down [back]: 6.0 vs 8.6; and walking slowly: 6.8 vs 7.7 bpm), whereas the Samsung Galaxy Watch Active2 performed better during and after low- and high-intensity activities (standing up: 12.3 vs 9.0; walking fast: 6.1 vs 5.8; stairs: 8.8 vs 6.9; squats: 15.7 vs 6.1; resting: 9.6 vs 5.6 bpm).

conclusionsDevice accuracy varied with activity. Overall, both devices achieved a mean absolute percentage error of just <10%. Thus, they were considered to produce valid results based on the limits established by previous work in the field. Neither device reached sufficient accuracy during seated rest or keyboard typing. Thus, both devices may be eligible for use in respective studies; however, researchers should consider their individual study requirements.

Indexed as

cardiovascularFitbitFitbit Charge 4fitnessfitness trackerfitness tracker accuracyheart rateheart rate accuracyheart rate validationSamsung Galaxy Watch Active2wearablewearable accuracywearable validation

Identifiers

PMID35230250
PMCPMC8924780

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.