Evidence map›Paper›PMID 35227740›Full record

ArticleJournal of neuroscience methods2022

Focused ultrasound stimulation of an ex-vivo Aplysia abdominal ganglion preparation.

Tomas Jordan, James M Newcomb, Michael B Hoppa, Geoffrey P Luke

Open access · greenAbstract read
In one paragraph

Article in Journal of neuroscience methods, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.5field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Use of an invertebrate animal model (Frontiers in neuroscience · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Tomas JordanThayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA.
James M NewcombDepartment of Biology and Health Science, New England College, Henniker, NH 03242, USA.
Michael B HoppaDepartment of Biological Sciences, Dartmouth College, Hanover, NH 03755, USA.
Geoffrey P LukeThayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA. Electronic address: Geoffrey.p.luke@dartmouth.edu.
Dartmouth College · USNew England College · US

Funding

Ultrastructural analysis of axonal Kv2-mediated endoplasmic reticulum/plasma membrane (ER/PM) junctionsP20GM103506 · NIGMS · DARTMOUTH COLLEGE · PI Yina Hsing Huang · 2012 to 2026
$60.1M
Remote Neurostimulation with Ultrasound-activated Piezoelectric NanoparticlesR21EY029422 · NEI · DARTMOUTH COLLEGE · PI LUKE, GEOFFREY P. · 2018 to 2019
$634k
Ultrasound neurostimulation with piezoelectric nanoparticlesR03NS118125 · NINDS · DARTMOUTH COLLEGE · PI LUKE, GEOFFREY P. · 2021 to 2022
$156k
NEI NIH HHS R21 EY029422NIGMS NIH HHS P20 GM103506NINDS NIH HHS R03 NS118125
6 · The paper itself

Abstract

backgroundA growing body of research demonstrates that focused ultrasound stimulates activity in human and other mammalian nervous systems. However, there is no consensus on which sonication parameters are optimal. Furthermore, the mechanism of action behind ultrasound neurostimulation remains poorly understood. An invertebrate model greatly reduces biological complexity, permitting a systematic evaluation of sonication parameters suitable for ultrasound neurostimulation. NEW

methodHere, we describe the use of focused ultrasound stimulation with an ex-vivo abdominal ganglion preparation of the California sea hare, Aplysia californica, a long-standing model system in neurobiology. We developed a system for stimulating an isolated ganglion preparation while obtaining extracellular recordings from nerves. The focused ultrasound stimulation uses one of two single-element transducers, enabling stimulation at four distinct carrier frequencies (0.515 MHz, 1.l MHz, 1.61 MHz, 3.41 MHz).

resultsUsing continuous wave ultrasound, we stimulated the ganglion at all four frequencies, and we present quantitative evaluation of elicited activation at four different sonication durations and three peak pressure levels, eliciting up to a 57-fold increase in spiking frequency. COMPARISON WITH ELECTRICAL STIMULATION: We demonstrated that ultrasound-induced activation is repeatable, and the response consistency is comparable to electrical stimulation.

conclusionsDue to the relative ease of long-term recordings for many hours, this ex-vivo ganglion preparation is suitable for investigating sonication parameters and the effects of focused ultrasound stimulation on neurons.

Indexed as

AplysiaNeuronsAnimalsElectric StimulationHumansMammalsTransducersAbdominal ganglionAplysia californicaFocused ultrasoundUltrasound neurostimulation

Identifiers

PMID35227740
PMCPMC8978332
OpenAlexW4214771215

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.