ArticleAdvances in therapy2022
Cost-Effectiveness of Hybrid Closed Loop Insulin Pumps Versus Multiple Daily Injections Plus Intermittently Scanned Glucose Monitoring in People With Type 1 Diabetes in The Netherlands.
Article in Advances in therapy, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 2 syntheses or guidelines pooled it, 21 citations in OpenAlex.
- Hybrid closed-loop systems for managing blood glucose levels in type 1 diabetes: a systematic review and economic modelling.Health technology assessment (Winchester, England) · 2024Pooled it
- Evaluating the Cost-Utility of Continuous Glucose Monitoring in Individuals with Type 1 Diabetes: A Systematic Review of the Methods and Quality of Studies Using Decision Models or Empirical Data.PharmacoEconomics · 2024Pooled it
- Insulin pump therapy for T1D: a real-world analysis of a novel two-in-one insulin pump in Chinese adults with type 1 diabetes.Diabetology & metabolic syndrome · 2026Article
- Preliminary clinical outcomes and adoption of continuous glucose monitoring following reimbursement implementation in patients with type 1 diabetes in Thailand.Annals of pediatric endocrinology & metabolism · 2026Article
- Economic analyses of freestyle libre systems for people living with diabetes: a systematic literature review.Cost effectiveness and resource allocation : C/E · 2025Review
- Long-term health economic evaluation of automated insulin delivery system compared with continuous subcutaneous insulin infusion pumps and CGM in a real-world setting in Finnish paediatric and adult individuals with type 1 diabetes.Diabetes, obesity & metabolism · 2025Article
- Differences in Metabolic Control Between Different Insulin Use Patterns in Pediatric Patients with Type 1 Diabetes Through Intermittent Glucose Monitoring.Diseases (Basel, Switzerland) · 2025Article
- Closed-loop therapy: recent advancements and potential predictors of glycemic outcomes.Expert opinion on drug delivery · 2025Review
- The role of advanced technologies in improving diabetes outcomes.The American journal of managed care · 2025Review
- Combining Glucose Monitoring and Insulin Infusion in an Integrated Device: A Narrative Review of Challenges and Proposed Solutions.Journal of diabetes science and technology · 2025Review
- Letter to the Editor Regarding Cost-Effectiveness of Hybrid Closed-Loop Systems Versus Multiple Daily Injections Plus Intermittently-Scanned Continuous Glucose Monitoring in Type 1 Diabetes in the Netherlands.Advances in therapy · 2023Article
- Closed-loop insulin delivery: update on the state of the field and emerging technologies.Expert review of medical devices · 2022Review
Corrections and comments
- Commented on by
- Commented on by
Authors and funding
6 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionHybrid closed loop (HCL) insulin pump systems and intermittently scanned continuous glucose monitoring (IS-CGM) are increasingly used by individuals with type 1 diabetes (T1D). The aim of the analysis was to compare the long-term cost-effectiveness of the MiniMed 670G HCL system versus IS-CGM plus multiple daily injections of insulin (MDI) or continuous subcutaneous insulin infusion (CSII) in adults with T1D in the Netherlands.
methodsThe analysis was performed using the IQVIA CORE Diabetes Model with clinical input data sourced from observational studies. Simulated patients were assumed to have a baseline HbA1c of 7.8%. Use of the MiniMed 670G system was assumed to reduce HbA1c by 0.4% and confer a quality-of-life (QoL) benefit through reduced fear of hypoglycemia (FoH). The analysis was performed from a societal perspective over a lifetime time horizon; future costs and clinical outcomes pertaining to the Netherlands were used and discounted at 4% and 1.5% per annum, respectively.
resultsUse of the MiniMed 670G HCL system was projected to improve mean quality-adjusted life expectancy by 2.231 quality-adjusted life years (QALYs) versus IS-CGM. Total mean lifetime costs were EUR 13,683 higher with the MiniMed 670G system resulting in an ICER of EUR 6133 per QALY gained. Sensitivity analyses revealed findings to be sensitive to changes in assumptions around severe hypoglycemic event rates and the (QoL) benefit associated with reduced FoH.
conclusionsOver patient lifetimes, for adults with long-standing T1D in the Netherlands, use of the MiniMed 670G system is projected to be cost-effective versus IS-CGM plus MDI or CSII.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials