Evidence map›Paper›PMID 35224747›Full record

ArticleMedical physics2022

Technical note: A PET/MR coil with an integrated, orbiting 511 keV transmission source for PET/MR imaging validated in an animal study.

Andreas Renner, Ivo Rausch, Jacobo Cal Gonzalez, Elmar Laistler, Ewald Moser, Thies Jochimsen, Tatjana Sattler, Osama Sabri, Thomas Beyer, Michael Figl and 2 more

Abstract read
In one paragraph

Article in Medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Andreas RennerCenter for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria.
Ivo RauschCenter for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria.
Jacobo Cal GonzalezCenter for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria.
Elmar LaistlerCenter for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria.
Ewald MoserCenter for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria.
Thies JochimsenDepartment of Nuclear Medicine, University Hospital Leipzig, Leipzig, Germany.
Tatjana SattlerClinic for Ruminants and Swine, University of Leipzig, Leipzig, Germany.
Osama SabriDepartment of Nuclear Medicine, University Hospital Leipzig, Leipzig, Germany.
Thomas BeyerCenter for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria.
Michael FiglCenter for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria.
Wolfgang BirkfellnerCenter for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria.
Bernhard SattlerDepartment of Nuclear Medicine, University Hospital Leipzig, Leipzig, Germany.

Funding

The financial support of the Austrian Science Fund (FWF) Project P27853-B30 is gratefully acknowledged.
6 · The paper itself

Abstract

backgroundMR-based methods for attenuation correction (AC) in PET/MRI either neglect attenuation of bone, or use MR-signal derived information about bone, which leads to a bias in quantification of tracer uptake in PET. In a previous study, we presented a PET/MRI specific MR coil with an integrated transmission source (TX) system allowing for direct measurement of attenuation. In phantom measurements, this system successfully reproduced the linear attenuation coefficient of water. PURPOSE: The purpose of this study is to validate the TX system in a clinical setting using animals and to show its applicability compared to standard clinical methods.

methodsAs test subject, a 15-kg piglet was injected with 53 MBq of 18F-NaF. The μ-map obtained with the TX system and the reconstructed activity distribution were compared to four established AC methods: a Dixon sequence, an ultra-short echo time (UTE) sequence, a CT scan, and a 511 keV transmission scan using a Siemens ECAT EXACT HR+ as the reference. The PET/MRI measurements were performed on a Siemens Biograph mMR to obtain the μ-map using the TX system as well as the Dixon and UTE sequence directly followed by the CT and ECAT measurements.

resultsThe reconstructed activity distribution using the TX system for AC showed similar results compared to the reference (<5% difference in hot regions) and outperformed the MR-based methods as implemented in the PET/MRI system (<10% difference in hot regions). However, the additional hardware of the TX system adds complexity to the acquisition process.

conclusionOur porcine study demonstrates the feasibility of post-injection transmission scans using the developed TX system in a clinical setting. This makes it a useful tool for PET/MRI in cases where transmission information is needed for AC. Potential applications are studies using larger animals where state-of-the-art atlas-based or artificial intelligence AC methods are not available.

Indexed as

Artificial IntelligenceMultimodal ImagingAnimalsImage Processing, Computer-AssistedMagnetic Resonance ImagingPhantoms, ImagingPositron-Emission TomographySwineattenuation correctionMRIPETpost-injectiontransmission source

Identifiers

PMID35224747
PMCPMC9310742

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.