Evidence map›Paper›PMID 35224486›Full record

ArticleFrontiers in sports and active living2022

Detection of Homologous Blood Transfusion in Sport Doping by Flow Cytofluorimetry: State of the Art and New Approaches to Reduce the Risk of False-Negative Results.

Francesco Donati, Xavier de la Torre, Sarajane Pagliarosi, Daniela Pirri, Giuliana Prevete, Francesco Botrè

Open access · goldAbstract read
In one paragraph

Article in Frontiers in sports and active living, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.1field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Article
  7. Future opportunities for the Athlete Biological Passport.Frontiers in sports and active living · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Francesco DonatiLaboratorio Antidoping, Federazione Medico Sportiva Italiana, Rome, Italy.
Xavier de la TorreLaboratorio Antidoping, Federazione Medico Sportiva Italiana, Rome, Italy.
Sarajane PagliarosiLaboratorio Antidoping, Federazione Medico Sportiva Italiana, Rome, Italy.
Daniela PirriLaboratorio Antidoping, Federazione Medico Sportiva Italiana, Rome, Italy.
Giuliana PreveteLaboratorio Antidoping, Federazione Medico Sportiva Italiana, Rome, Italy.
Francesco BotrèLaboratorio Antidoping, Federazione Medico Sportiva Italiana, Rome, Italy.
Federazione Medico Sportiva Italiana · ITUniversity of Lausanne · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This article presents the results of a study aimed to give new suggestions and strategies for improving the implementation of the flow cytofluorimetry-based method for the detection of homologous blood transfusions in doping control. The method is based on the recognition of the phenotypic mismatch between minority blood group antigens possessed by the donor and the recipient. Two strategies have been followed to reduce the risk of false-negative results: (i) the monitoring of a broader range of erythrocytes surface antigens; and (ii) the application of different surface erythrocyte staining protocols, tailored on the different antigens and the type of antigenic mismatch that had to be detected (whether it is the donor or the recipient who expresses or not the antigen to be detected). Special attention has also been focused on the time factor, to avoid prolonged sample storage, since hemolysis may have a significant impact on the reliability and quality of the results. Our experimental evidence suggests that the risk of false-negative results can be minimized by (i) the expansion of the antigen panel, with the inclusion of four additional targets; (ii) a more accurate selection of the gating area of the red blood cells; (iii) the choice of a better fluorochrome (alexa fluor 488) to be conjugated to the secondary antibody; and (iv) the implementation of different staining protocols depending on the nature of the double population to be detected (donor expressing vs. recipient non-expressing and vice versa). The combination of the above approaches allowed a significant reduction of false-negative results, assessed on samples simulating a homologous blood transfusion between two compatible subjects.

Indexed as

doping controlflow cytometryhomologous blood transfusionshuman blood groupsred blood cell surface antigens

Identifiers

PMID35224486
PMCPMC8866641
OpenAlexW4211184425

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.