Evidence map›Paper›PMID 35222882›Full record

ArticleJournal of healthcare engineering2022

Ultrasound Calibration for Dual-Armed Surgical Navigation System.

Kuan-Ju Wang, Chieh-Hsiao Chen, Chun-Yi Lo, Hung-Hsin Lin, Jia-Jin Jason Chen

Open access · hybridAbstract read
In one paragraph

Article in Journal of healthcare engineering, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 55% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Robot-assisted ultrasound probe calibration for image-guided interventions.International journal of computer assisted radiology and surgery · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Kuan-Ju WangDepartment of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.ORCID 0000-0002-9842-1617
Chieh-Hsiao ChenBrain Navi Biotechnology Co. Ltd, Zhubei, Hsinchu Country, Taiwan.
Chun-Yi LoBrain Navi Biotechnology Co. Ltd, Zhubei, Hsinchu Country, Taiwan.
Hung-Hsin LinBrain Navi Biotechnology Co. Ltd, Zhubei, Hsinchu Country, Taiwan.
Jia-Jin Jason ChenDepartment of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.ORCID 0000-0003-2751-5066
National Cheng Kung University · TWChina Medical University · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Ultrasound (US) imaging system is widely used in robotic systems for precision positioning in clinical applications. The US calibration is critical to minimize the difference of spatial coordinates between instruments, for minimally invasive surgery (MIS) in navigation systems. In this study, we propose a dual robotic arm system that combines US imaging with one arm for path planning and monitoring and accurate positioning with the other arm for instrument placement via the preplanning procedures. A phantom with N-wire and N-wedge was designed for US calibration. The US calibration showed a mean error of 0.76 mm; the mean dual-arm calibration error is 0.31 mm. The positioning error of the system was verified with a mean error of 1.48 mm. In addition, we used two abdominal phantoms with computed tomography scan validation, with an averaged position error of 1.867 ± 0.436 mm and an orientation error of 2.190 ± 0.764°. The proposed system is aimed to perform clinical operations, such as abdominal MIS, with real-time image monitoring of the organ tissues and instrument positions, which meet the requirements for medical application.

Indexed as

Surgery, Computer-AssistedSurgical Navigation SystemsCalibrationHumansImaging, Three-DimensionalPhantoms, ImagingTomography, X-Ray ComputedUltrasonography

Identifiers

PMID35222882
PMCPMC8866004
OpenAlexW4213257631

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.