Evidence map›Paper›PMID 35217676›Full record

ArticleScientific reports2022

Effects of training and using an audio-tactile sensory substitution device on speech-in-noise understanding.

K Cieśla, T Wolak, A Lorens, M Mentzel, H Skarżyński, A Amedi

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
10.3field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 56 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

K CieślaThe Baruch Ivcher Institute for Brain, Cognition & Technology, The Baruch Ivcher School of Psychology and the Ruth and Meir Rosental Brain Imaging Center, Reichman University, Herzliya, Israel. kasia.j.ciesla@gmail.com.
T WolakWorld Hearing Centre, Institute of Physiology and Pathology of Hearing, Warsaw, Poland.
A LorensWorld Hearing Centre, Institute of Physiology and Pathology of Hearing, Warsaw, Poland.
M MentzelThe Baruch Ivcher Institute for Brain, Cognition & Technology, The Baruch Ivcher School of Psychology and the Ruth and Meir Rosental Brain Imaging Center, Reichman University, Herzliya, Israel.
H SkarżyńskiWorld Hearing Centre, Institute of Physiology and Pathology of Hearing, Warsaw, Poland.
A AmediThe Baruch Ivcher Institute for Brain, Cognition & Technology, The Baruch Ivcher School of Psychology and the Ruth and Meir Rosental Brain Imaging Center, Reichman University, Herzliya, Israel.
Institute of Physiology and Pathology of Hearing · PLReichman University · IL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Understanding speech in background noise is challenging. Wearing face-masks, imposed by the COVID19-pandemics, makes it even harder. We developed a multi-sensory setup, including a sensory substitution device (SSD) that can deliver speech simultaneously through audition and as vibrations on the fingertips. The vibrations correspond to low frequencies extracted from the speech input. We trained two groups of non-native English speakers in understanding distorted speech in noise. After a short session (30-45 min) of repeating sentences, with or without concurrent matching vibrations, we showed comparable mean group improvement of 14-16 dB in Speech Reception Threshold (SRT) in two test conditions, i.e., when the participants were asked to repeat sentences only from hearing and also when matching vibrations on fingertips were present. This is a very strong effect, if one considers that a 10 dB difference corresponds to doubling of the perceived loudness. The number of sentence repetitions needed for both types of training to complete the task was comparable. Meanwhile, the mean group SNR for the audio-tactile training (14.7 ± 8.7) was significantly lower (harder) than for the auditory training (23.9 ± 11.8), which indicates a potential facilitating effect of the added vibrations. In addition, both before and after training most of the participants (70-80%) showed better performance (by mean 4-6 dB) in speech-in-noise understanding when the audio sentences were accompanied with matching vibrations. This is the same magnitude of multisensory benefit that we reported, with no training at all, in our previous study using the same experimental procedures. After training, performance in this test condition was also best in both groups (SRT ~ 2 dB). The least significant effect of both training types was found in the third test condition, i.e. when participants were repeating sentences accompanied with non-matching tactile vibrations and the performance in this condition was also poorest after training. The results indicate that both types of training may remove some level of difficulty in sound perception, which might enable a more proper use of speech inputs delivered via vibrotactile stimulation. We discuss the implications of these novel findings with respect to basic science. In particular, we show that even in adulthood, i.e. long after the classical "critical periods" of development have passed, a new pairing between a certain computation (here, speech processing) and an atypical sensory modality (here, touch) can be established and trained, and that this process can be rapid and intuitive. We further present possible applications of our training program and the SSD for auditory rehabilitation in patients with hearing (and sight) deficits, as well as healthy individuals in suboptimal acoustic situations.

Indexed as

COVID-19Speech PerceptionAdultHumansNoiseSpeechTouch

Identifiers

PMID35217676
PMCPMC8881456
OpenAlexW4214545628

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.