Evidence map›Paper›PMID 35214785›Full record

ArticleVaccines2022

Decline of Humoral Responses 6 Months after Vaccination with BNT162b2 (Pfizer-BioNTech) in Patients on Hemodialysis.

Michael Jahn, Johannes Korth, Oliver Dorsch, Olympia Evdoxia Anastasiou, Adalbert Krawczyk, Leonie Brochhagen, Lukas van de Sand, Burkhard Sorge-Hädicke, Bartosz Tyczynski, Oliver Witzke and 4 more

Open access · goldAbstract read
In one paragraph

Article in Vaccines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.9field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors at 2 institutions in 1 country.

Michael JahnDepartment of Nephrology, University Hospital Essen, University of Duisburg-Essen, 45147 Essen, Germany.ORCID 0000-0002-7493-205X
Johannes KorthDepartment of Nephrology, University Hospital Essen, University of Duisburg-Essen, 45147 Essen, Germany.ORCID 0000-0003-4898-0389
Oliver DorschKfH Kuratorium für Dialyse und Nierentransplantation e.V, Friesener Straße 37a, 96317 Kronach, Germany.
Olympia Evdoxia AnastasiouInstitute for Virology, University Hospital Essen, University of Duisburg-Essen, Virchowstr. 179, 45147 Essen, Germany.ORCID 0000-0003-2178-3182
Adalbert KrawczykDepartment of Infectious Diseases, West German Centre of Infectious Diseases, University Hospital Essen, University of Duisburg-Essen, Hufelandstr. 55, 45147 Essen, Germany.ORCID 0000-0001-9502-9903
Leonie BrochhagenDepartment of Infectious Diseases, West German Centre of Infectious Diseases, University Hospital Essen, University of Duisburg-Essen, Hufelandstr. 55, 45147 Essen, Germany.
Lukas van de SandDepartment of Infectious Diseases, West German Centre of Infectious Diseases, University Hospital Essen, University of Duisburg-Essen, Hufelandstr. 55, 45147 Essen, Germany.ORCID 0000-0001-5122-4213
Burkhard Sorge-HädickeKfH Kuratorium für Dialyse und Nierentransplantation e.V, Alfried-Krupp-Str. 43, 45131 Essen, Germany.
Bartosz TyczynskiDepartment of Nephrology, University Hospital Essen, University of Duisburg-Essen, 45147 Essen, Germany.
Oliver WitzkeDepartment of Infectious Diseases, West German Centre of Infectious Diseases, University Hospital Essen, University of Duisburg-Essen, Hufelandstr. 55, 45147 Essen, Germany.
Ulf DittmerInstitute for Virology, University Hospital Essen, University of Duisburg-Essen, Virchowstr. 179, 45147 Essen, Germany.
Sebastian DolffDepartment of Infectious Diseases, West German Centre of Infectious Diseases, University Hospital Essen, University of Duisburg-Essen, Hufelandstr. 55, 45147 Essen, Germany.ORCID 0000-0001-5549-1706
Benjamin WildeDepartment of Nephrology, University Hospital Essen, University of Duisburg-Essen, 45147 Essen, Germany.
Andreas KribbenDepartment of Nephrology, University Hospital Essen, University of Duisburg-Essen, 45147 Essen, Germany.
University of Duisburg-Essen · DEKfH Kuratorium für Dialyse und Nierentransplantation · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study analyzed binding and neutralizing antibody titers up to 6 months after standard vaccination with BNT162b2 (two doses of 30 µg each) in SARS-CoV-2 naïve patients (n = 59) on hemodialysis. Humoral vaccine responses were measured before and 6, 12, and 24 weeks after the first vaccination. A chemiluminescent immunoassay (CLIA) was used to quantify SARS-CoV-2 IgG against the spike glycoprotein. SARS-CoV-2 neutralizing activity was tested against the wild-type virus. A multivariable binary regression model was used to identify risk factors for the absence of humoral immune responses at 6 months. At week 6, vaccine-specific seroconversion was detected in 96.6% of all patients with median anti-SARS-CoV-2 IgGs of 918 BAU/mL. At weeks 12 and 24, seroconversion rates decreased to 91.5% and 79.7%, and corresponding median binding antibody titers declined to 298 BAU/mL and 89 BAU/mL, respectively. Neutralizing antibodies showed a decay from 79.6% at week 6 to 32.8% at week 24. The risk factor with the strongest association for vanishing immune responses was low serum albumin (

Indexed as

anti-SARS-CoV-2 IgGBNT162b2chronic kidney diseaseCOVID-19hemodialysismRNA vaccinesneutralizing antibodies

Identifiers

PMID35214785
PMCPMC8878048
OpenAlexW4212915083

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.