Evidence map›Paper›PMID 35214525›Full record

ArticleSensors (Basel, Switzerland)2022

Negative Index Metamaterial-Based Frequency-Reconfigurable Textile CPW Antenna for Microwave Imaging of Breast Cancer.

Kabir Hossain, Thennarasan Sabapathy, Muzammil Jusoh, Shen-Han Lee, Khairul Shakir Ab Rahman, Muhammad Ramlee Kamarudin

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
  5. A novel textile-based UWB patch antenna for breast cancer imaging.Physical and engineering sciences in medicine · 2024
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kabir HossainAdvanced Communication Engineering (ACE), Centre of Excellence, Universiti Malaysia Perlis (UniMAP), Jalan Tiga, Pengkalan Jaya Business Centre, Kangar 01000, Malaysia.ORCID 0000-0002-1020-4272
Thennarasan SabapathyAdvanced Communication Engineering (ACE), Centre of Excellence, Universiti Malaysia Perlis (UniMAP), Jalan Tiga, Pengkalan Jaya Business Centre, Kangar 01000, Malaysia.ORCID 0000-0002-9235-7132
Muzammil JusohAdvanced Communication Engineering (ACE), Centre of Excellence, Universiti Malaysia Perlis (UniMAP), Jalan Tiga, Pengkalan Jaya Business Centre, Kangar 01000, Malaysia.ORCID 0000-0003-3870-6773
Shen-Han LeeDepartment of Otorhinolaryngology, Hospital Sultanah Bahiyah, KM6 Jalan Langgar, Alor Setar 05460, Malaysia.ORCID 0000-0002-6147-2963
Khairul Shakir Ab RahmanDepartment of Pathology, Hospital Tuanku Fauziah, Kangar 01000, Malaysia.
Muhammad Ramlee KamarudinFaculty of Electrical and Electronic Engineering, Universiti Tun Hussein Onn Malaysia (UTHM), Parit Raja, Batu Pahat 86400, Malaysia.

Funding

Ministry of Higher Education Malaysia FRGS/1/2019/TK04/UNIMAP/02/3
6 · The paper itself

Abstract

In this paper, we report the design and development of a metamaterial (MTM)-based directional coplanar waveguide (CPW)-fed reconfigurable textile antenna using radiofrequency (RF) varactor diodes for microwave breast imaging. Both simulation and measurement results of the proposed MTM-based CPW-fed reconfigurable textile antenna revealed a continuous frequency reconfiguration to a distinct frequency band between 2.42 GHz and 3.2 GHz with a frequency ratio of 2.33:1, and with a static bandwidth at 4-15 GHz. The results also indicated that directional radiation pattern could be produced at the frequency reconfigurable region and the antenna had a peak gain of 7.56 dBi with an average efficiency of more than 67%. The MTM-based reconfigurable antenna was also tested under the deformed condition and analysed in the vicinity of the breast phantom. This microwave imaging system was used to perform simulation and measurement experiments on a custom-fabricated realistic breast phantom with heterogeneous tissue composition with image reconstruction using delay-and-sum (DAS) and delay-multiply-and-sum (DMAS) algorithms. Given that the MWI system was capable of detecting a cancer as small as 10 mm in the breast phantom, we propose that this technique may be used clinically for the detection of breast cancer.

Indexed as

Breast NeoplasmsMicrowave ImagingDiagnostic ImagingFemaleHumansMicrowavesTextilesbreast cancercancermetamaterialsmicrowave imagingreconfigurable textile antennastextile antennas

Identifiers

PMID35214525
PMCPMC8878032

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.