Evidence map›Paper›PMID 35214471›Full record

ArticleSensors (Basel, Switzerland)2022

Automatic and Efficient Fall Risk Assessment Based on Machine Learning.

Nadav Eichler, Shmuel Raz, Adi Toledano-Shubi, Daphna Livne, Ilan Shimshoni, Hagit Hel-Or

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Intelligent Sensors for Human Motion Analysis.Sensors (Basel, Switzerland) · 2022
    Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Nadav EichlerDepartment of Computer Science, University of Haifa, Haifa 3498838, Israel.
Shmuel RazDepartment of Information Systems, University of Haifa, Haifa 3498838, Israel.
Adi Toledano-ShubiPhysiotherapy Institute, Galilee Medical Center, Chicago, IL 60639, USA.
Daphna LivnePhysiotherapy Institute, Galilee Medical Center, Chicago, IL 60639, USA.
Ilan ShimshoniDepartment of Information Systems, University of Haifa, Haifa 3498838, Israel.ORCID 0000-0002-5276-0242
Hagit Hel-OrDepartment of Computer Science, University of Haifa, Haifa 3498838, Israel.ORCID 0000-0001-8488-0380

Funding

Israel Innovation Authority dockets 63436 and 67323Israel Science Foundation 1455/16
6 · The paper itself

Abstract

Automating fall risk assessment, in an efficient, non-invasive manner, specifically in the elderly population, serves as an efficient means for implementing wide screening of individuals for fall risk and determining their need for participation in fall prevention programs. We present an automated and efficient system for fall risk assessment based on a multi-depth camera human motion tracking system, which captures patients performing the well-known and validated Berg Balance Scale (BBS). Trained machine learning classifiers predict the patient's 14 scores of the BBS by extracting spatio-temporal features from the captured human motion records. Additionally, we used machine learning tools to develop fall risk predictors that enable reducing the number of BBS tasks required to assess fall risk, from 14 to 4-6 tasks, without compromising the quality and accuracy of the BBS assessment. The reduced battery, termed Efficient-BBS (E-BBS), can be performed by physiotherapists in a traditional setting or deployed using our automated system, allowing an efficient and effective BBS evaluation. We report on a pilot study, run in a major hospital, including accuracy and statistical evaluations. We show the accuracy and confidence levels of the E-BBS, as well as the average number of BBS tasks required to reach the accuracy thresholds. The trained E-BBS system was shown to reduce the number of tasks in the BBS test by approximately 50% while maintaining 97% accuracy. The presented approach enables a wide screening of individuals for fall risk in a manner that does not require significant time or resources from the medical community. Furthermore, the technology and machine learning algorithms can be implemented on other batteries of medical tests and evaluations.

Indexed as

Accidental FallsPostural BalanceAgedHumansMachine LearningPilot ProjectsRisk AssessmentbalanceBerg Balance Scalediagnosiselderlyfall risk detectionhuman trackingtelemedicine

Identifiers

PMID35214471
PMCPMC8875808

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.