Evidence map›Paper›PMID 35214234›Full record

ArticleSensors (Basel, Switzerland)2022

A Wearable System Based on Multiple Magnetic and Inertial Measurement Units for Spine Mobility Assessment: A Reliability Study for the Evaluation of Ankylosing Spondylitis.

Adriana Martínez-Hernández, Juan S Perez-Lomelí, Ruben Burgos-Vargas, Miguel A Padilla-Castañeda

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
5.2field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 25 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Adriana Martínez-HernándezApplied Science and Technology Institute (ICAT), National Autonomous University of Mexico (UNAM), Mexico City 04510, Mexico.ORCID 0000-0003-3003-2495
Juan S Perez-LomelíApplied Science and Technology Institute (ICAT), National Autonomous University of Mexico (UNAM), Mexico City 04510, Mexico.
Ruben Burgos-VargasRheumatology Service Unit, General Hospital of Mexico "Dr. Eduardo Liceaga", Mexico City 06720, Mexico.
Miguel A Padilla-CastañedaApplied Science and Technology Institute (ICAT), National Autonomous University of Mexico (UNAM), Mexico City 04510, Mexico.ORCID 0000-0002-1389-2074
Universidad Nacional Autónoma de México · MXHospital General de México · MX

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Spinal mobility assessment is essential for the diagnostic of patients with ankylosing spondylitis. BASMI is a routine clinical evaluation of the spine; its measurements are made with goniometers and tape measures, implying systematic errors, subjectivity, and low sensitivity. Therefore, it is crucial to develop better mobility assessment methods. The design, implementation, and evaluation of a novel system for assessing the entire spine's motion are presented. It consists of 16 magnetic and inertial measurement units (MIMUs) communicated wirelessly with a computer. The system evaluates the patient's movements by implementing a sensor fusion of the triaxial gyroscope, accelerometer, and magnetometer signals using a Kalman filter. Fifteen healthy participants were assessed with the system through six movements involving the entire spine to calculate continuous kinematics and maximum range of motion (RoM). The intrarater reliability was computed over the observed RoM, showing excellent reliability levels (intraclass correlation >0.9) in five of the six movements. The results demonstrate the feasibility of the system for further clinical studies with patients. The system has the potential to improve the BASMI method. To the best of our knowledge, our system involves the highest number of sensors, thus providing more objective information than current similar systems.

Indexed as

Spondylitis, AnkylosingWearable Electronic DevicesHumansMagnetic PhenomenaRange of Motion, ArticularReproducibility of ResultsSeverity of Illness IndexSpineankylosing spondylitishuman movementinertial measurement unitsKalman filterspine

Identifiers

PMID35214234
PMCPMC8875397
OpenAlexW4211263226

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.