Evidence map›Paper›PMID 35213588›Full record

ArticlePloS one2022

The influence of corn trypsin inhibitor on the contribution of coagulation determinants to the Technoclone Thrombin Generation Assay (TGA) and the Calibrated Automated Thrombogram (CAT).

Carolina E Touw, Ype de Jong, Astrid van Hylckama Vlieg

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
0.2field-weighted citation impact, top 53% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it, 3 citations in OpenAlex.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Carolina E TouwDepartment of Clinical Epidemiology, Leiden University Medical Center, Leiden, the Netherlands.ORCID 0000-0002-7993-5209
Ype de JongDepartment of Clinical Epidemiology, Leiden University Medical Center, Leiden, the Netherlands.ORCID 0000-0002-7805-1508
Astrid van Hylckama VliegDepartment of Clinical Epidemiology, Leiden University Medical Center, Leiden, the Netherlands.
Leiden University Medical Center · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In thrombin generation (TG) assays, regarded as global coagulation tests, contact activation is considered a major problem which can be eliminated by adding Corn Trypsin Inhibitor (CTI). In previous studies, however, venous thrombosis risk prediction using TG assays did not improve after CTI addition. However, it is unknown whether CTI addition could help to detect subtle but relevant nuances in determinants of TG, making the assay more suitable to detect disturbances in the coagulation system. This study's objective was to assess whether the addition of CTI is associated with a broader contribution of individual coagulation factors to the total amount of thrombin formed in Calibrated Automated Thrombogram (CAT) and Technoclone Thrombin Generation Assay (TGA). Thrombin generation was measured in 326 healthy individuals from THE VTE study at very low tissue factor concentrations, with and without addition of CTI prior to blood sampling. The influence of several coagulation factors on total amount of thrombin formed, i.e. area under the curve (AUC) or endogenous thrombin potential (ETP), was analysed using multiple linear regression with standardisation of all values resulting in Z-scores with 95% confidence intervals (95%CI). Association between coagulation factors and TG changed minimally after addition of CTI. Largest changes after CTI addition were found for following factors: for CAT: free protein S (from 0.00 (95%CI -0.12 to 0.12) to -0.29 (95%CI -0.43 to -0.15)) and protein S (from -0.05 (95%CI -0.18 to 0.08) to -0.21 (95%CI -0.37 to -0.05)); for TGA: antithrombin (from -0.11 (-0.23 to 0.02) to -0.19 (-0.30 to -0.07)), factor VIII (from 0.15 (0.03 to 0.27) to 0.24 (0.13 to 0.36)) and fibrinogen (from 0.12 (-0.01 to 0.26) to 0.19 (0.06 to 0.32)). In conclusion, there is no clear trend towards a broader contribution of coagulation factors in samples handled with CTI compared with those handled without CTI.

Indexed as

AdolescentAdultAgedAged, 80 and overBlood Coagulation TestsCalibrationFemaleHumansMaleMiddle AgedPlant ProteinsThrombinVenous ThrombosisPlant ProteinsThrombintrypsin inhibitor, Zea mays

Identifiers

PMID35213588
PMCPMC8880747
OpenAlexW4214621695

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.