Evidence map›Paper›PMID 35213564›Full record

ArticlePloS one2022

Plasma generated ozone and reactive oxygen species for point of use PPE decontamination system.

Min Huang, Md Kamrul Hasan, Kavita Rathore, Md Abdullah Hil Baky, John Lassalle, Jamie Kraus, Matthew Burnette, Christopher Campbell, Kunpeng Wang, Howard Jemison and 3 more

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.9field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 15 citations in OpenAlex.

  1. Bundesgesundheitsblatt, Gesundheitsforschung, Gesundheitsschutz · 2026
    Article
  2. Article
  3. Article
  4. Review
  5. Electron beam technology for Re-processing of personal protective equipment.Radiation physics and chemistry (Oxford, England : 1993) · 2023
    Article
  6. Bundesgesundheitsblatt, Gesundheitsforschung, Gesundheitsschutz · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 1 institution in 1 country.

Min HuangDepartment of Mechanical Engineering, Texas A&M University, College Station, Texas, United States of America.ORCID 0000-0002-5662-6219
Md Kamrul HasanDepartment of Mechanical Engineering, Texas A&M University, College Station, Texas, United States of America.ORCID 0000-0003-3612-7284
Kavita RathoreDepartment of Mechanical Engineering, Texas A&M University, College Station, Texas, United States of America.
Md Abdullah Hil BakyDepartment of Mechanical Engineering, Texas A&M University, College Station, Texas, United States of America.
John LassalleDepartment of Mechanical Engineering, Texas A&M University, College Station, Texas, United States of America.ORCID 0000-0002-0572-6842
Jamie KrausDepartment of Mechanical Engineering, Texas A&M University, College Station, Texas, United States of America.
Matthew BurnetteDepartment of Mechanical Engineering, Texas A&M University, College Station, Texas, United States of America.
Christopher CampbellDepartment of Mechanical Engineering, Texas A&M University, College Station, Texas, United States of America.
Kunpeng WangLTEOIL LLC, Houston, Texas, United States of America.
Howard JemisonLTEOIL LLC, Houston, Texas, United States of America.
Suresh PillaiCenter for Electron Beam Food Research, Texas A&M University, College Station, Texas, United States of America.
Matt PharrDepartment of Mechanical Engineering, Texas A&M University, College Station, Texas, United States of America.
David StaackDepartment of Mechanical Engineering, Texas A&M University, College Station, Texas, United States of America.
Texas A&M University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper reports a plasma reactive oxygen species (ROS) method for decontamination of PPE (N95 respirators and gowns) using a surface DBD source to meet the increased need of PPE due to the COVID-19 pandemic. A system is presented consisting of a mobile trailer (35 m3) along with several Dielectric barrier discharge sources installed for generating a plasma ROS level to achieve viral decontamination. The plasma ROS treated respirators were evaluated at the CDC NPPTL, and additional PPE specimens and material functionality testing were performed at Texas A&M. The effects of decontamination on the performance of respirators were tested using a modified version of the NIOSH Standard Test Procedure TEB-APR-STP-0059 to determine particulate filtration efficiency. The treated Prestige Ameritech and BYD brand N95 respirators show filtration efficiencies greater than 95% and maintain their integrity. The overall mechanical and functionality tests for plasma ROS treated PPE show no significant variations.

Indexed as

Personal Protective EquipmentReactive Oxygen SpeciesCOVID-19DecontaminationEquipment ReuseHumansN95 RespiratorsReactive Oxygen Species

Identifiers

PMID35213564
PMCPMC8880944
OpenAlexW4214762096

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.