The flagging features of the Sysmex XN-10 analyser for detecting platelet clumps and the impacts of platelet clumps on complete blood count parameters.

Peng Xu, Kui Fang, Xiling Chen, Yangruiqi Liu, Zheqing Dong, Ji Zhu, Keda Lu

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical chemistry and laboratory medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Peng XuZhejiang Chinese Medical University Affiliated Third Hospital, Hangzhou, P.R. China.
Kui FangZhejiang Chinese Medical University Affiliated Third Hospital, Hangzhou, P.R. China.
Xiling ChenZhejiang Chinese Medical University Affiliated Third Hospital, Hangzhou, P.R. China.
Yangruiqi LiuZhejiang Chinese Medical University Affiliated Third Hospital, Hangzhou, P.R. China.
Zheqing DongZhejiang Chinese Medical University Affiliated Third Hospital, Hangzhou, P.R. China.
Ji ZhuZhejiang Chinese Medical University Affiliated Third Hospital, Hangzhou, P.R. China.
Keda LuZhejiang Chinese Medical University Affiliated Third Hospital, Hangzhou, P.R. China.
The Third Affiliated Hospital of Zhejiang Chinese Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesPlatelet clumps present in anticoagulant specimens may generate a falsely decreased platelet count and lead to an incorrect diagnosis. A clear understanding of the ability of a haematology analyser (HA) to detect platelet clumps is important for routine work in the clinical laboratory.

methodsCitrate-anticoagulated whole-blood samples were collected from various patients as a negative group. Adenosine diphosphate (ADP)-induced platelet aggregation was performed on those negative samples to mimic platelet-clump-containing (positive) samples. The 'platelet clumps' and 'platelet abnormal' flags generated by the Sysmex XN-10 instrument were used to assess the flagging performance of this HA and demonstrate its flagging features. The complete blood count (CBC) results of paired negative and positive samples were compared to evaluate the impact of platelet clumps on the CBC parameters.

resultsA total of 187 samples were eligible for this study. The total accuracy, sensitivity, and specificity of the platelet clumps flag were 0.786, 0.626, and 0.947, respectively. The total accuracy, sensitivity, and specificity of the platelet abnormal flag were 0.631, 0.348, and 0.914, respectively. A separate assessment focusing on the positive samples with low platelet counts showed that the total sensitivities of the platelet clumps and platelet abnormal flags were 0.801 and 1.000, respectively. Platelet clumps may interfere with the leukocyte count and with platelet and erythrocyte indices.

conclusionsPlatelet clumps can influence not only platelet indices but also leukocyte and erythrocyte counts. The Sysmex XN-10 instrument is sensitive to positive samples with low platelet counts but insensitive to those with high platelet counts.

Indexed as

HematologyLeukocytesBlood Cell CountHumansLeukocyte CountPlatelet Countcomplete blood countflagging qualityhaematology analyserplatelet aggregates

Identifiers

PMID35212492
OpenAlexW4214525385

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.