ArticleBMC musculoskeletal disorders2022
Radius distraction during volar plating of distal radius fractures may improve distal radioulnar joint stability at minimum 3-year follow-up: a retrospective case series study.
Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 6 citations in OpenAlex.
- Complications after volar plate synthesis for distal radius fractures.EFORT open reviews · 2024Article
- Bridge Plate Distraction for Complex Distal Radius Fractures: A Cohort Study and Systematic Review of the Literature.Journal of wrist surgery · 2024Article
- Treatment of distal radius fractures using a cemented K-wire frame.BMC musculoskeletal disorders · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe surgical technique of radius distraction for stabilization of distal radioulnar joint (DRUJ) if intraoperative DRUJ instability was found after the fixation of distal radius fracture has been previously described, but this surgical technique lacks clinical and radiographic effect in minimal 3 years follow-up. We therefore evaluated the clinical outcome and radiographic results of radius distraction in minimal 3 years follow-up as long-term evaluation.
methodsWe reviewed the case series of distal radius fracture with concomitant DRUJ instability receiving radius distraction from the senior author over a 5-year period (January 1
resultsAt minimal post-operative 36 months follow-up, all cases demonstrated acceptable wrist range of motion with stable DRUJs, low NRS of wrist pain (0.6, SD 0.7), and satisfactory DASH score (mean 9.1, SD 6.2) and MMWS score (mean 87, SD 10). There were no cases suffering from nonunion of distal radius. The mean ulnar variance of injured wrist and uninjured wrist were -1.2 mm and 0.2 mm, respectively (SD 1.0 and 0.6) with significant statistical difference.
conclusionsRadius distraction during volar fixation of distal radius fracture should be considered if DRUJ instability was found by the dorsopalmar stress test intraoperatively, and the long-term DRUJ stability could be achieved by maintenance of normal-to-negative ulnar variance, with decreased wrist pain and satisfactory function outcome. LEVEL OF EVIDENCE: Therapeutic Level IV.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.