Evidence map›Paper›PMID 35208463›Full record

ArticleMicromachines2022

A Thermocycler Using a Chip Resistor Heater and a Glass Microchip for a Portable and Rapid Microchip-Based PCR Device.

Dongsun Yeom, Jeongtae Kim, Sungil Kim, Sanghoon Ahn, Jiyeon Choi, Youngwook Kim, Chiwan Koo

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.3field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Dongsun YeomDepartment of Electronic Engineering, Hanbat National University, Daejeon 34158, Korea.ORCID 0000-0002-1602-4280
Jeongtae KimDepartment of Electronic Engineering, Hanbat National University, Daejeon 34158, Korea.
Sungil KimDepartment of Laser and Electron Beam Application, Korea Institute of Machinery and Materials, Daejeon 34103, Korea.ORCID 0000-0003-3756-2800
Sanghoon AhnDepartment of Laser and Electron Beam Application, Korea Institute of Machinery and Materials, Daejeon 34103, Korea.ORCID 0000-0001-5429-7653
Jiyeon ChoiDepartment of Laser and Electron Beam Application, Korea Institute of Machinery and Materials, Daejeon 34103, Korea.ORCID 0000-0002-0522-261X
Youngwook KimDepartment of Electronic Engineering, Sogang University, Seoul 04107, Korea.
Chiwan KooDepartment of Electronic Engineering, Hanbat National University, Daejeon 34158, Korea.ORCID 0000-0003-2880-1670
Hanbat National University · KRKorea Institute of Machinery & Materials · KRSogang University · KR

Funding

Hanbat National University 2017
6 · The paper itself

Abstract

This study proposes a rapid and inexpensive thermocycler that enables rapid heating of samples using a thin glass chip and a cheap chip resistor to overcome the on-site diagnostic limitations of polymerase chain reaction (PCR). Microchip PCR devices have emerged to miniaturize conventional PCR systems and reduce operation time and cost. In general, PCR microchips require a thin-film heater fabricated through a semiconductor process, which is a complicated process, resulting in high costs. Therefore, this investigation substituted a general chip resistor for a thin-film heater. The proposed thermocycler consists of a compact glass microchip of 12.5 mm × 12.5 mm × 2 mm that could hold a 2 μL PCR sample and a surface-mounted chip resistor of 6432 size (6.4 mm × 3.2 mm). Improving heat transfer from the chip resistor heater to the PCR reaction chamber in the microchip was accomplished via the design and fabrication of a three-dimensional chip structure using selective laser-induced etching, a rapid prototyping technique that allowed to be embedded. The fabricated PCR microchip was combined with a thermistor temperature sensor, a blower fan, and a microcontroller. The assembled thermocycler could heat the sample at a maximum rate of 28.8 °C/s per second. When compared with a commercially available PCR apparatus running the same PCR protocol, the total PCR operating time with a DNA sample was reduced by about 20%.

Indexed as

chip resistor heaterglass PCR microchippolymerase chain reactionSLE

Identifiers

PMID35208463
PMCPMC8876486
OpenAlexW4213151045

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.